SKU:SEA820Mu

ELISA Kit for Coagulation Factor II (F2)

ELISA Kit for Coagulation Factor II (F2)

Regular price $648.00 USD
Regular price Sale price $648.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEA820Mu

Organism Species

Mus musculus (Mouse).

Sample Type

serum

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

125-8,000ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 45ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

Specificity

This assay has high sensitivity and excellent specificity for detection of Coagulation Factor II (F2).
No significant cross-reactivity or interference between Coagulation Factor II (F2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Coagulation Factor II (F2) and the recovery rates were calculated by comparing the measured value to the expected amount of Coagulation Factor II (F2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-98 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Coagulation Factor II (F2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Coagulation Factor II (F2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Coagulation Factor II (F2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 95-105% 79-103% 88-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
Blood Cells Mol Dis Upregulation of cytokine signalling in platelets increases risk of thrombophilia in severe COVID-19 patients Pubmed:35180460
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA820Mu03 Recombinant Coagulation Factor II (F2) Positive Control; Immunogen; SDS-PAGE; WB.
RPA820Mu02 Recombinant Coagulation Factor II (F2) Positive Control; Immunogen; SDS-PAGE; WB.
RPA820Mu01 Recombinant Coagulation Factor II (F2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA820Mu03 Polyclonal Antibody to Coagulation Factor II (F2) WB; IHC; ICC; IP.
PAA820Mu02 Polyclonal Antibody to Coagulation Factor II (F2) WB; IHC; ICC; IP.
PAA820Mu01 Polyclonal Antibody to Coagulation Factor II (F2) WB; IHC; ICC; IP.
LAA820Mu81 FITC-Linked Polyclonal Antibody to Coagulation Factor II (F2) WB; IHC; ICC; IF.
LAA820Mu71 Biotin-Linked Polyclonal Antibody to Coagulation Factor II (F2) WB; IHC; ICC.
MAA820Mu22 Monoclonal Antibody to Coagulation Factor II (F2) WB; IHC; ICC; IP.
SEA820Mu ELISA Kit for Coagulation Factor II (F2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA820Mu Magnetic Luminex Assay Kit for Coagulation Factor II (F2) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSA820Mu01 ELISA Kit DIY Materials for Coagulation Factor II (F2) Main materials for "Do It (ELISA Kit) Yourself".
View full details