Cloud-clone
SKU:SEB034Hu
ELISA Kit for Mucin 4 (MUC4)
ELISA Kit for Mucin 4 (MUC4)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEB034Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
0.312-20ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.127ng/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Mucin 4 (MUC4).
No significant cross-reactivity or interference between Mucin 4 (MUC4) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Mucin 4 (MUC4) and the recovery rates were calculated by comparing the measured value to the expected amount of Mucin 4 (MUC4) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-92 | 82 |
| EDTA plasma(n=5) | 91-101 | 95 |
| heparin plasma(n=5) | 78-97 | 87 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mucin 4 (MUC4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mucin 4 (MUC4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mucin 4 (MUC4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 83-91% | 88-101% | 90-98% | 86-93% |
| EDTA plasma(n=5) | 80-102% | 81-97% | 86-103% | 99-105% |
| heparin plasma(n=5) | 91-99% | 85-97% | 95-105% | 99-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| Annals of surgical oncology | Pancreatic cyst fluid and serum mucin levels predict dysplasia in intraductal papillary mucinous neoplasms of the pancreas. PubMed: 20717734 |
| Exp Mol Pathol | The regulatory role of SFRP5/WNT5A axis in allergic rhinitis through inhibiting JNK pathway activation and lowering mucin generation in human nasal?¡ 33285209 |
| ISCIENCE | Identified human breastmilk compositions effectively inhibit SARS-CoV-2 and variants infection and replication Pubmed:35342878 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB034Hu01 | Recombinant Mucin 4 (MUC4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB034Hu01 | Polyclonal Antibody to Mucin 4 (MUC4) | WB; IHC; ICC; IP. |
| LAB034Hu71 | Biotin-Linked Polyclonal Antibody to Mucin 4 (MUC4) | WB; IHC; ICC. |
| MAB034Hu22 | Monoclonal Antibody to Mucin 4 (MUC4) | WB; IHC; ICC; IP. |
| SEB034Hu | ELISA Kit for Mucin 4 (MUC4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB034Hu | Magnetic Luminex Assay Kit for Mucin 4 (MUC4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share
