Skip to product information
1 of 1

Cloud-clone

SKU:SEA987Ra

ELISA Kit for Aldosterone Synthase (ALDOS)

ELISA Kit for Aldosterone Synthase (ALDOS)

Regular price $684.00 USD
Regular price Sale price $684.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEA987Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Serum, plasma, tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

0.156-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.057ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

Specificity

This assay has high sensitivity and excellent specificity for detection of Aldosterone Synthase (ALDOS).
No significant cross-reactivity or interference between Aldosterone Synthase (ALDOS) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Aldosterone Synthase (ALDOS) and the recovery rates were calculated by comparing the measured value to the expected amount of Aldosterone Synthase (ALDOS) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-88 85
EDTA plasma(n=5) 81-93 90
heparin plasma(n=5) 85-99 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aldosterone Synthase (ALDOS) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aldosterone Synthase (ALDOS) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Aldosterone Synthase (ALDOS) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-90% 92-105% 97-104% 96-104%
EDTA plasma(n=5) 88-97% 80-91% 81-103% 99-105%
heparin plasma(n=5) 94-103% 88-102% 81-104% 80-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
Journal of the Renin-AngiotensinAldosterone System A pilot investigation into the effects of acute normobaric hypoxia, high altitude exposure and exercise on serum angiotensin-converting enzyme, aldosterone and … Pubmed:29956573
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA987Ra01 Recombinant Aldosterone Synthase (ALDOS) Positive Control; Immunogen; SDS-PAGE; WB.
PAA987Ra01 Polyclonal Antibody to Aldosterone Synthase (ALDOS) WB; IHC; ICC; IP.
MAA987Ra21 Monoclonal Antibody to Aldosterone Synthase (ALDOS) WB; IHC; ICC; IP.
SEA987Ra ELISA Kit for Aldosterone Synthase (ALDOS) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA987Ra Magnetic Luminex Assay Kit for Aldosterone Synthase (ALDOS) ,etc. Magnetic Luminex Assay for Antigen Detection.
View full details