Cloud-clone
SKU:SEB868Hu
ELISA Kit for Metallothionein 2 (MT2)
ELISA Kit for Metallothionein 2 (MT2)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEB868Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
0.156-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.056ng/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Metallothionein 2 (MT2).
No significant cross-reactivity or interference between Metallothionein 2 (MT2) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Metallothionein 2 (MT2) and the recovery rates were calculated by comparing the measured value to the expected amount of Metallothionein 2 (MT2) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 92-99 | 95 |
| EDTA plasma(n=5) | 91-101 | 95 |
| heparin plasma(n=5) | 92-101 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Metallothionein 2 (MT2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Metallothionein 2 (MT2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Metallothionein 2 (MT2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 91-102% | 80-89% | 96-104% | 97-105% |
| EDTA plasma(n=5) | 91-101% | 79-98% | 84-103% | 84-104% |
| heparin plasma(n=5) | 90-102% | 80-101% | 87-95% | 92-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| Journal of Trace Elements in Medicine and Biology | Metallothionein 2A gene polymorphism and trace elements in mother-newborn pairs in the Croatian population pubmed:29173474 |
| Biochimica et Biophysica Acta | GCN2 deficiency protects against high fat diet induced hepatic steatosis and insulin resistance in mice Pubmed:30006154 |
| Arch Virol . | Infectious bronchitis virus inhibits activation of the TLR7 pathway, but not the TLR3 pathway Pubmed: 32532134 |
| Biomolecules | Mercury Exposure Assessment in Mother–Infant Pairs from Continental and Coastal Croatia Pubmed: 32471193 |
| Analytica Chimica Acta | Gold nanoclusters as elemental label for the sequential quantification of apolipoprotein E and metallothionein 2A in individual human cells of the retinal … Pubmed:35361429 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB868Hu01 | Recombinant Metallothionein 2 (MT2) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB868Hu01 | Polyclonal Antibody to Metallothionein 2 (MT2) | WB; IHC; ICC; IP. |
| LAB868Hu81 | FITC-Linked Polyclonal Antibody to Metallothionein 2 (MT2) | WB; IHC; ICC; IF. |
| LAB868Hu71 | Biotin-Linked Polyclonal Antibody to Metallothionein 2 (MT2) | WB; IHC; ICC. |
| MAB868Hu22 | Monoclonal Antibody to Metallothionein 2 (MT2) | WB; IHC; ICC; IP. |
| SEB868Hu | ELISA Kit for Metallothionein 2 (MT2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB868Hu | Magnetic Luminex Assay Kit for Metallothionein 2 (MT2) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share