Cloud-clone
SKU:SEA214Ga
ELISA Kit for Caveolin 1 (CAV1)
ELISA Kit for Caveolin 1 (CAV1)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEA214Ga
Organism Species
Chicken (Gallus).
Sample Type
serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
0.156-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.057ng/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Caveolin 1 (CAV1).
No significant cross-reactivity or interference between Caveolin 1 (CAV1) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Caveolin 1 (CAV1) and the recovery rates were calculated by comparing the measured value to the expected amount of Caveolin 1 (CAV1) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 84-102 | 94 |
| EDTA plasma(n=5) | 84-94 | 90 |
| heparin plasma(n=5) | 88-98 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Caveolin 1 (CAV1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Caveolin 1 (CAV1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Caveolin 1 (CAV1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 98-105% | 83-94% | 92-99% | 98-105% |
| EDTA plasma(n=5) | 82-91% | 84-101% | 88-102% | 88-102% |
| heparin plasma(n=5) | 81-104% | 99-105% | 80-102% | 97-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| Mendel Net | Novel prostate cancer tumour markers in a cell line model Mendelu: source |
| Oncology reports | Caveolin-1 as a potential high-risk prostate cancer biomarker PubMed: 22159333 |
| Anticancer Research | Increased plasma caveolin-1 levels are associated with progression of prostate cancer among Japanese men Pubmed: 23645736 |
| Sarcoidosis Vasc Diffuse Lung Dis.? | Decrased sputum caveolin-1 is associated with systemic sclerosis related lung disease Pubmed:24751454 |
| Cancer Genomics and Proteomics | Significant Association of Caveolin-1 and Caveolin-2 with Prostate Cancer Progression PubMed: 26543085 |
| Atherosclerosis | Genomic variant in CAV1 increases susceptibility to coronary artery disease and myocardial infarction Pubmed:26775120 |
| Arthritis Research & Therapy | Increased caveolin-1 in intervertebral disc degeneration facilitates repair Pubmed:26939667 |
| Oxid Med Cell Longev | Lower Serum Caveolin-1 Is Associated with Cerebral Microbleeds in Patients with Acute Ischemic Stroke Pubmed:27119011 |
| Inflammation | Caveolin-1 Promotes the Imbalance of Th17/Treg in Patients with Chronic Obstructive PulmonaryDisease. pubmed:27613621 |
| Oxidative Medicine and Cellular Longevity | Swim Training Modulates Skeletal Muscle Energy Metabolism, Oxidative Stress, and Mitochondrial Cholesterol Content in Amyotrophic Lateral Sclerosis Mice Pubmed:29849903 |
| Microcirculation | Endothelium‐dependent hyperpolarization‐mediated vasodilatation compensates nitric oxide‐mediated endothelial dysfunction during ischemia in diabetes‐induced … Pubmed:29665152 |
| Genetic Testing and Molecular Biomarkers | The CAV1 Gene 3′ Untranslated Region Single Nucleotide Polymorphisms Are Associated with the Risk of Pulmonary Hypertension in Chinese Han Chronic … |
| Cell Rep | SIRT6 transcriptionally regulates fatty acid transport by suppressing PPAR¦Ã 34077730 |
| researchsquare | Cav-1 Protein Levels in Serum and Infarcted Brain Correlate with Hemorrhagic Volume in a Mouse Model of Thromboembolic Stroke, Independently of Rt-PA?¡ |
| Molecules | 5, 2′-Dibromo-2, 4′, 5′-trihydroxydiphenylmethanone Inhibits LPS-Induced Vascular Inflammation by Targeting the Cav1 Protein Pubmed:35566232 |
| Catalog No. | Related products for research use of Chicken (Gallus) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA214Ga01 | Recombinant Caveolin 1 (CAV1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA214Ga01 | Polyclonal Antibody to Caveolin 1 (CAV1) | WB; IHC; ICC; IP. |
| MAA214Ga21 | Monoclonal Antibody to Caveolin 1 (CAV1) | WB; IHC; ICC; IP. |
| SEA214Ga | ELISA Kit for Caveolin 1 (CAV1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA214Ga | Magnetic Luminex Assay Kit for Caveolin 1 (CAV1) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share