Cloud-clone
SKU:SEA940Mu
ELISA Kit for Chemokine C-X-C-Motif Receptor 4 (CXCR4)
ELISA Kit for Chemokine C-X-C-Motif Receptor 4 (CXCR4)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEA940Mu
Organism Species
Mus musculus (Mouse).
Sample Type
tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
78-5,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 33pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Chemokine C-X-C-Motif Receptor 4 (CXCR4).
No significant cross-reactivity or interference between Chemokine C-X-C-Motif Receptor 4 (CXCR4) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-X-C-Motif Receptor 4 (CXCR4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-X-C-Motif Receptor 4 (CXCR4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| International Journal of Cancer | Inhibition of CXCR4/CXCL12 signaling axis by ursolic acid leads to suppression of metastasis in transgenic adenocarcinoma of mouse prostate model Wiley: source |
| Plos one | Emodin Suppresses Migration and Invasion through the Modulation of CXCR4 Expression in an Orthotopic Model of Human Hepatocellular Carcinoma PubMed: PMC3589458 |
| Atherosclerosis | The non-alcoholic fraction of beer increases stromal cell derived factor 1 and the number of circulating endothelial progenitor cells in high cardiovascular risk subjects: A randomized clinical trial Pubmed:24530788 |
| Pharmacol Rep.? | Comparison of chemokines (CCL-5 and SDF-1), chemokine receptors (CCR-5 and CXCR-4) and IL-6 levels in patients with different severities of depression Pubmed:25150002 |
| Pharmacological Reports | Serum concentrations of chemokines (CCL-5 and CXCL-12), chemokine receptors (CCR-5 and CXCR-4), and IL-6 in patients with posttraumatic stress disorder and avoidant personality disorder PubMed: 26481549 |
| Pharmacological Reports | A study of chemokines, chemokine receptors and interleukin-6 in patients with panic disorder, personality disorders and their co-morbidity Pubmed:27208878 |
| BMC Cancer. | Enhancement of the CXCL12/CXCR4 axis due to acquisition of gemcitabine resistance in pancreatic cancer: effect of CXCR4 antagonists pmc:PMC4866076 |
| Frontiers in Bioengineering and Biotechnology | Matrix Metalloproteinase-2 Impairs Homing of Intracoronary Delivered Mesenchymal Stem Cells in a Porcine Reperfused Myocardial Infarction: Comparison … Pubmed:29670878 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA940Mu01 | Recombinant Chemokine C-X-C-Motif Receptor 4 (CXCR4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA940Mu02 | Recombinant Chemokine C-X-C-Motif Receptor 4 (CXCR4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA940Mu02 | Polyclonal Antibody to Chemokine C-X-C-Motif Receptor 4 (CXCR4) | WB; IHC; ICC; IP. |
| PAA940Mu01 | Polyclonal Antibody to Chemokine C-X-C-Motif Receptor 4 (CXCR4) | WB; IHC; ICC; IP. |
| SEA940Mu | ELISA Kit for Chemokine C-X-C-Motif Receptor 4 (CXCR4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA940Mu | Magnetic Luminex Assay Kit for Chemokine C-X-C-Motif Receptor 4 (CXCR4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share
