Cloud-clone
SKU:SEB939Ra
ELISA Kit for Syndecan 4 (SDC4)
ELISA Kit for Syndecan 4 (SDC4)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEB939Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
31.2-2,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 13.3pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Syndecan 4 (SDC4).
No significant cross-reactivity or interference between Syndecan 4 (SDC4) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Syndecan 4 (SDC4) and the recovery rates were calculated by comparing the measured value to the expected amount of Syndecan 4 (SDC4) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 87-103 | 99 |
| EDTA plasma(n=5) | 85-94 | 90 |
| heparin plasma(n=5) | 95-105 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Syndecan 4 (SDC4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Syndecan 4 (SDC4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Syndecan 4 (SDC4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 93-105% | 95-102% | 93-101% | 87-101% |
| EDTA plasma(n=5) | 78-98% | 80-88% | 80-93% | 82-93% |
| heparin plasma(n=5) | 82-102% | 98-105% | 94-103% | 79-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| Lipids in Health and Disease | The influence of atorvastatin on parameters of inflammation left ventricular function, hospitalizations and mortality in patients with dilated cardiomyopathy–5-year follow-up PubMed: PMC3641983 |
| The FASEB Journal | Matrix metalloproteinase 9-mediated shedding of syndecan 4 in response to tumor necrosis factor α: a contributor to endothelial cell glycocalyx dysfunction Pubmed:25122554 |
| Scientific Reports | Biomarkers and Echocardiographic Predictors of Myocardial Dysfunction in Patients with Hypertension PubMed: 25747153 |
| Int J Mol Sci | The Multi-Biomarker Approach for Heart Failure in Patients with Hypertension PubMed: 25984599 |
| Biochemical and Biophysical Research Communications | Syndecan-4 shedding impairs macrovascular angiogenesis in diabetes mellitus Pubmed:27018253 |
| Kidney International | Aldosterone induces albuminuria via matrix metalloproteinase–dependent damage of the endothelial glycocalyx Pubmed: 30389198 |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB939Ra01 | Recombinant Syndecan 4 (SDC4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB939Ra01 | Polyclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC; IP. |
| LAB939Ra71 | Biotin-Linked Polyclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC. |
| LAB939Ra81 | FITC-Linked Polyclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC; IF. |
| MAB939Ra21 | Monoclonal Antibody to Syndecan 4 (SDC4) | WB; IHC; ICC; IP. |
| SEB939Ra | ELISA Kit for Syndecan 4 (SDC4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB939Ra | Magnetic Luminex Assay Kit for Syndecan 4 (SDC4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share