Cloud-clone
SKU:CCA856Hu
CLIA Kit for Apelin 12 (AP12)
CLIA Kit for Apelin 12 (AP12)
Couldn't load pickup availability
Chemiluminescent immunoassay for Antigen Detection.
Product No.
CCA856Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
2h
Detection Range
62.5-16,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 22.8pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Apelin 12 (AP12).
No significant cross-reactivity or interference between Apelin 12 (AP12) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Apelin 12 (AP12) and the recovery rates were calculated by comparing the measured value to the expected amount of Apelin 12 (AP12) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 79-92 | 88 |
| EDTA plasma(n=5) | 82-89 | 86 |
| heparin plasma(n=5) | 80-98 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apelin 12 (AP12) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apelin 12 (AP12) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apelin 12 (AP12) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 81-99% | 82-101% | 91-105% | 91-99% |
| EDTA plasma(n=5) | 79-101% | 94-105% | 99-105% | 89-103% |
| heparin plasma(n=5) | 90-97% | 85-94% | 92-99% | 88-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| Substrate A | 1×10mL | Substrate B | 1×2mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
| Magazine | Citations |
| Clinical and Experimental Hypertension | Serum concentrations of apelin-17 isoform vary in accordance to blood pressure categories in individuals with obesity class 3 Pubmed:29652188 |
| Pediatr Diabetes | Adropin and apelin‐12 efficiently predict metabolic syndrome in obese children Pubmed: 32749012 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| PAA856Hu01 | Polyclonal Antibody to Apelin 12 (AP12) | WB; IHC; ICC; IP. |
| LAA856Hu71 | Biotin-Linked Polyclonal Antibody to Apelin 12 (AP12) | WB; IHC; ICC. |
| CEA856Hu | ELISA Kit for Apelin 12 (AP12) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CCA856Hu | CLIA Kit for Apelin 12 (AP12) | Chemiluminescent immunoassay for Antigen Detection. |
| LMA856Hu | Magnetic Luminex Assay Kit for Apelin 12 (AP12) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
| KSA856Hu11 | ELISA Kit DIY Materials for Apelin 12 (AP12) | Main materials for "Do It (ELISA Kit) Yourself". |
Share