Skip to product information
1 of 1

Cloud-clone

SKU:SEE671Hu

ELISA Kit for SHC-Transforming Protein 1 (SHC1)

ELISA Kit for SHC-Transforming Protein 1 (SHC1)

Regular price $700.00 USD
Regular price Sale price $700.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEE671Hu

Organism Species

Homo sapiens (Human).

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

0.312-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.117ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

Specificity

This assay has high sensitivity and excellent specificity for detection of SHC-Transforming Protein 1 (SHC1).
No significant cross-reactivity or interference between SHC-Transforming Protein 1 (SHC1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level SHC-Transforming Protein 1 (SHC1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level SHC-Transforming Protein 1 (SHC1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
Eur Neuropsychopharmacol. Regulation of insulin receptor phosphorylation in the brains of prenatally stressed rats: New insight into the benefits of antidepressant drug treatment. pubmed:28063625
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPE671Hu01 Recombinant SHC-Transforming Protein 1 (SHC1) Positive Control; Immunogen; SDS-PAGE; WB.
PAE671Hu01 Polyclonal Antibody to SHC-Transforming Protein 1 (SHC1) WB; IHC; ICC; IP.
MAE671Hu21 Monoclonal Antibody to SHC-Transforming Protein 1 (SHC1) WB; IHC; ICC; IP.
SEE671Hu ELISA Kit for SHC-Transforming Protein 1 (SHC1) Enzyme-linked immunosorbent assay for Antigen Detection.
LME671Hu Magnetic Luminex Assay Kit for SHC-Transforming Protein 1 (SHC1) ,etc. Magnetic Luminex Assay for Antigen Detection.
View full details