Cloud-clone
SKU:SCA709Hu
CLIA Kit for Toll Like Receptor 9 (TLR9)
CLIA Kit for Toll Like Receptor 9 (TLR9)
Couldn't load pickup availability
Chemiluminescent immunoassay for Antigen Detection.
Product No.
SCA709Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
2h, 40min
Detection Range
2.74-2,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.99pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Toll Like Receptor 9 (TLR9).
No significant cross-reactivity or interference between Toll Like Receptor 9 (TLR9) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Toll Like Receptor 9 (TLR9) and the recovery rates were calculated by comparing the measured value to the expected amount of Toll Like Receptor 9 (TLR9) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 88-102 | 97 |
| EDTA plasma(n=5) | 88-103 | 95 |
| heparin plasma(n=5) | 88-96 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Toll Like Receptor 9 (TLR9) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Toll Like Receptor 9 (TLR9) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Toll Like Receptor 9 (TLR9) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 97-105% | 83-91% | 98-105% | 78-89% |
| EDTA plasma(n=5) | 78-102% | 82-94% | 95-102% | 85-102% |
| heparin plasma(n=5) | 79-101% | 86-103% | 80-101% | 81-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| Substrate A | 1×10mL | Substrate B | 1×2mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
| Magazine | Citations |
| Chinese Medical Journal | Expression of soluble Toll-like receptors in pleural effusions CMJ: 2010823483999506297 |
| DNA Cell Biol. | Expression of serum toll-like receptor 9 and oxidative damage markers in benign and malignant breast diseases Pubmed:24906089 |
| Journal of Trace Elements in Medicine and Biology | Correlation of serum toll like receptor 9 and trace elements with lipid peroxidation in the patients of breast diseases PubMed: 25744504 |
| Journal of cancer research and clinical oncology | TLR9 gene polymorphism− 1486T/C (rs187084) is associated with uterine cervical neoplasm in Mexican female population pubmed:28819773 |
| In Vivo | The Relationship Between Sepsis-induced Immunosuppression and Serum Toll-like Receptor 9 Level Pubmed: 30348730 |
| The role of toll-like receptor 9 (TLR9) in Epstein-Barr virus-associated gastric cancer |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA709Hu01 | Recombinant Toll Like Receptor 9 (TLR9) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA709Hu01 | Polyclonal Antibody to Toll Like Receptor 9 (TLR9) | WB; IHC; ICC; IP. |
| MAA709Hu22 | Monoclonal Antibody to Toll Like Receptor 9 (TLR9) | WB; IHC; ICC; IP. |
| HEA709Hu | High Sensitive ELISA Kit for Toll Like Receptor 9 (TLR9) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SEA709Hu | ELISA Kit for Toll Like Receptor 9 (TLR9) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCA709Hu | CLIA Kit for Toll Like Receptor 9 (TLR9) | Chemiluminescent immunoassay for Antigen Detection. |
| LMA709Hu | Magnetic Luminex Assay Kit for Toll Like Receptor 9 (TLR9) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
| KSA709Hu01 | ELISA Kit DIY Materials for Toll Like Receptor 9 (TLR9) | Main materials for "Do It (ELISA Kit) Yourself". |
Share