Cloud-clone
SKU:SCB009Ra
CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)
CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR)
Couldn't load pickup availability
Chemiluminescent immunoassay for Antigen Detection.
Product No.
SCB009Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
2h, 40min
Detection Range
68.6-50,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 27.9pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Very Low Density Lipoprotein Receptor (VLDLR).
No significant cross-reactivity or interference between Very Low Density Lipoprotein Receptor (VLDLR) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Very Low Density Lipoprotein Receptor (VLDLR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Very Low Density Lipoprotein Receptor (VLDLR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| Substrate A | 1×10mL | Substrate B | 1×2mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
| Magazine | Citations |
| Food and Chemical Toxicology | Quercetin ameliorates HFD-induced NAFLD by promoting hepatic VLDL assembly and lipophagy via the IRE1a/XBP1s pathway Pubmed:29438776 |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB009Ra01 | Recombinant Very Low Density Lipoprotein Receptor (VLDLR) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB009Ra01 | Polyclonal Antibody to Very Low Density Lipoprotein Receptor (VLDLR) | WB; IHC; ICC; IP. |
| MAB009Ra21 | Monoclonal Antibody to Very Low Density Lipoprotein Receptor (VLDLR) | WB; IHC; ICC; IP. |
| SEB009Ra | ELISA Kit for Very Low Density Lipoprotein Receptor (VLDLR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCB009Ra | CLIA Kit for Very Low Density Lipoprotein Receptor (VLDLR) | Chemiluminescent immunoassay for Antigen Detection. |
| LMB009Ra | Magnetic Luminex Assay Kit for Very Low Density Lipoprotein Receptor (VLDLR) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share