Cloud-clone
SKU:SCB312Mu
CLIA Kit for Secretory Leukocyte Peptidase Inhibitor (SLPI)
CLIA Kit for Secretory Leukocyte Peptidase Inhibitor (SLPI)
Couldn't load pickup availability
Chemiluminescent immunoassay for Antigen Detection.
Product No.
SCB312Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Serum, plasma and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
2h, 40min
Detection Range
1.37-1,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.64pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Secretory Leukocyte Peptidase Inhibitor (SLPI).
No significant cross-reactivity or interference between Secretory Leukocyte Peptidase Inhibitor (SLPI) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Secretory Leukocyte Peptidase Inhibitor (SLPI) and the recovery rates were calculated by comparing the measured value to the expected amount of Secretory Leukocyte Peptidase Inhibitor (SLPI) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 89-96 | 92 |
| EDTA plasma(n=5) | 78-90 | 85 |
| heparin plasma(n=5) | 93-105 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Secretory Leukocyte Peptidase Inhibitor (SLPI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Secretory Leukocyte Peptidase Inhibitor (SLPI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Secretory Leukocyte Peptidase Inhibitor (SLPI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 84-99% | 91-98% | 88-105% | 93-101% |
| EDTA plasma(n=5) | 78-92% | 93-105% | 90-99% | 88-99% |
| heparin plasma(n=5) | 95-105% | 79-90% | 78-104% | 80-91% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| Substrate A | 1×10mL | Substrate B | 1×2mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
| Magazine | Citations |
| Human Immunology | Serum alarm antiproteases in systemic sclerosis patients pubmed:28606626 |
| The Journal of Toxicological Sciences | Editor's Highlight: Candidate Risk Factors and Mechanisms for Tolvaptan-Induced Liver Injury Are Identified Using a Collaborative Cross Approach pubmed:28115652 |
Share