Skip to product information
1 of 1

Cloud-clone

SKU:SEC036Eq

ELISA Kit for Transferrin (TF)

ELISA Kit for Transferrin (TF)

Regular price $602.00 USD
Regular price Sale price $602.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEC036Eq

Organism Species

Equus caballus; Equine (Horse).

Sample Type

Serum, plasma and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

78.12-5000ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 34ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

Specificity

This assay has high sensitivity and excellent specificity for detection of Transferrin (TF).
No significant cross-reactivity or interference between Transferrin (TF) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Transferrin (TF) and the recovery rates were calculated by comparing the measured value to the expected amount of Transferrin (TF) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-96 80
EDTA plasma(n=5) 96-105 102
heparin plasma(n=5) 92-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Transferrin (TF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Transferrin (TF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Transferrin (TF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-98% 94-105% 96-103% 94-103%
EDTA plasma(n=5) 83-101% 89-103% 85-103% 84-99%
heparin plasma(n=5) 89-96% 98-105% 80-101% 81-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
PLoS ONE Identification of Altered Plasma Proteins by Proteomic Study in Valvular Heart Diseases and the Potential Clinical Significance PubMed: PMC3754973
Physiological research The Labile Iron Pool in Monocytes Reflects the Activity of the Atherosclerotic Process in Men with Chronic Cardiovascular Disease pubmed:27782743
Journal of Proteomics Putative salivary biomarkers useful to differentiate patients with fibromyalgia Pubmed:29654921
Journal of Clinical Medicine Urinary Proteomics for the Early Diagnosis of Diabetic Nephropathy in Taiwanese Patients Pubmed: 30486327
The Nigerian postgraduate medical journal the official publication of the National Postgraduate Medical College of Nigeria Assessment of iron deficiency anaemia and its risk factors among adults with chronic kidney disease in a tertiary hospital in Nigeria
Haematologica New thiazolidinones reduce iron overload in mouse models of hereditary hemochromatosis and β-thalassemia Pubmed: 30792208
Catalog No. Related products for research use of Equus caballus; Equine (Horse) Organism species Applications (RESEARCH USE ONLY!)
RPC036Eq01 Recombinant Transferrin (TF) Positive Control; Immunogen; SDS-PAGE; WB.
PAC036Eq01 Polyclonal Antibody to Transferrin (TF) WB; IHC; ICC; IP.
MAC036Eq21 Monoclonal Antibody to Transferrin (TF) WB; IHC; ICC; IP.
SEC036Eq ELISA Kit for Transferrin (TF) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC036Eq Magnetic Luminex Assay Kit for Transferrin (TF) ,etc. Magnetic Luminex Assay for Antigen Detection.
View full details