Cloud-clone
SKU:SEC216Mu
ELISA Kit for E1A Binding Protein P300 (EP300)
ELISA Kit for E1A Binding Protein P300 (EP300)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEC216Mu
Organism Species
Mus musculus (Mouse).
Sample Type
tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
0.156-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.055ng/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of E1A Binding Protein P300 (EP300).
No significant cross-reactivity or interference between E1A Binding Protein P300 (EP300) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level E1A Binding Protein P300 (EP300) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level E1A Binding Protein P300 (EP300) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| BMJ Open Diabetes Research & Care | miR-200b Mediates Endothelial-to-Mesenchymal Transition in Diabetic Cardiomyopathy Pubmed:26718496 |
| Nature Communications | Reducing histone acetylation rescues cognitive deficits in a mouse model of Fragile X syndrome Pubmed:29950602 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPC216Mu01 | Recombinant E1A Binding Protein P300 (EP300) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPC216Mu02 | Recombinant E1A Binding Protein P300 (EP300) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAC216Mu01 | Polyclonal Antibody to E1A Binding Protein P300 (EP300) | WB; IHC; ICC; IP. |
| PAC216Mu02 | Polyclonal Antibody to E1A Binding Protein P300 (EP300) | WB; IHC; ICC; IP. |
| SEC216Mu | ELISA Kit for E1A Binding Protein P300 (EP300) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMC216Mu | Magnetic Luminex Assay Kit for E1A Binding Protein P300 (EP300) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share