Skip to product information
1 of 1

Cloud-clone

SKU:SEA750Ra

ELISA Kit for Complement Receptor 2 (CD21)

ELISA Kit for Complement Receptor 2 (CD21)

Regular price $684.00 USD
Regular price Sale price $684.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEA750Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Serum, plasma and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

1.56-100ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.57ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Complement Receptor 2 (CD21).
No significant cross-reactivity or interference between Complement Receptor 2 (CD21) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Complement Receptor 2 (CD21) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Receptor 2 (CD21) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-104 91
EDTA plasma(n=5) 87-104 97
heparin plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Receptor 2 (CD21) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Receptor 2 (CD21) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Receptor 2 (CD21) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 97-105% 78-97% 95-103%
EDTA plasma(n=5) 97-105% 79-95% 94-102% 93-101%
heparin plasma(n=5) 96-103% 78-97% 78-104% 88-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
journal of neuroinflammation Complement receptor 2 is up regulated in the spinal cord following nerve root injury and modulates the spinal cord response PubMed: 26502875
Clin Immunol Complement Receptor 2 is increased in cerebrospinal fluid of multiple sclerosis patients and reCavia (Guinea pig )lates C3 function Pubmed:27085202
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA750Ra01 Recombinant Complement Receptor 2 (CD21) Positive Control; Immunogen; SDS-PAGE; WB.
PAA750Ra01 Polyclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
MAA750Ra21 Monoclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
SEA750Ra ELISA Kit for Complement Receptor 2 (CD21) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA750Ra Magnetic Luminex Assay Kit for Complement Receptor 2 (CD21) ,etc. Magnetic Luminex Assay for Antigen Detection.
View full details