Skip to product information
1 of 1

Cloud-clone

SKU:SEC158Ra

ELISA Kit for Collagen Type XII (COL12)

ELISA Kit for Collagen Type XII (COL12)

Regular price $760.00 USD
Regular price Sale price $760.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEC158Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Serum, plasma and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

0.312-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.134ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Collagen Type XII (COL12).
No significant cross-reactivity or interference between Collagen Type XII (COL12) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Collagen Type XII (COL12) and the recovery rates were calculated by comparing the measured value to the expected amount of Collagen Type XII (COL12) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-96 86
EDTA plasma(n=5) 94-102 97
heparin plasma(n=5) 95-102 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Collagen Type XII (COL12) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Collagen Type XII (COL12) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Collagen Type XII (COL12) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-105% 78-97% 93-101% 78-104%
EDTA plasma(n=5) 94-102% 80-105% 83-93% 83-104%
heparin plasma(n=5) 97-105% 79-98% 96-105% 87-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPC158Ra01 Recombinant Collagen Type XII (COL12) Positive Control; Immunogen; SDS-PAGE; WB.
PAC158Ra01 Polyclonal Antibody to Collagen Type XII (COL12) WB; IHC; ICC; IP.
MAC158Ra21 Monoclonal Antibody to Collagen Type XII (COL12) WB; IHC; ICC; IP.
SEC158Ra ELISA Kit for Collagen Type XII (COL12) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC158Ra Magnetic Luminex Assay Kit for Collagen Type XII (COL12) ,etc. Magnetic Luminex Assay for Antigen Detection.
View full details