Cloud-clone
SKU:SCB372Hu
CLIA Kit for Serpin B3 (SERPINB3)
CLIA Kit for Serpin B3 (SERPINB3)
Couldn't load pickup availability
Chemiluminescent immunoassay for Antigen Detection.
Product No.
SCB372Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
2h, 40min
Detection Range
13.7-10,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 5.4pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Serpin B3 (SERPINB3).
No significant cross-reactivity or interference between Serpin B3 (SERPINB3) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Serpin B3 (SERPINB3) and the recovery rates were calculated by comparing the measured value to the expected amount of Serpin B3 (SERPINB3) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 93-105 | 101 |
| EDTA plasma(n=5) | 85-92 | 89 |
| heparin plasma(n=5) | 88-97 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Serpin B3 (SERPINB3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Serpin B3 (SERPINB3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Serpin B3 (SERPINB3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 87-95% | 94-103% | 93-105% | 98-105% |
| EDTA plasma(n=5) | 80-94% | 93-102% | 86-104% | 93-104% |
| heparin plasma(n=5) | 88-101% | 78-101% | 78-89% | 82-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| Substrate A | 1×10mL | Substrate B | 1×2mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
| Magazine | Citations |
| PLOS ONE | Susceptibility to COPD: Differential Proteomic Profiling after Acute Smoking Pubmed:25036363 |
| Annals of Clinical Biochemistry | Diagnostic specificity and sensitivity of PIVKAII, GP3, CSTB, SCCA1 and HGF for the diagnosis of hepatocellular carcinoma in patients with alcoholic liver cirrhosis. pubmed:28766361 |
| Head & neck | Combination of serum squamous cell carcinoma antigens 1 and 2 as potential diagnostic marker for sinonasal squamous cell carcinoma and inverted papilloma Pubmed: 30376194 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB372Hu02 | Recombinant Serpin B3 (SERPINB3) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB372Hu01 | Recombinant Serpin B3 (SERPINB3) | Positive Control; Immunogen; SDS-PAGE; WB. |
| EPB372Hu61 | Eukaryotic Serpin B3 (SERPINB3) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB372Hu03 | Recombinant Serpin B3 (SERPINB3) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB372Hu01 | Polyclonal Antibody to Serpin B3 (SERPINB3) | WB; ICC; IHC-P; IHC-F; ELISA. |
| PAB372Hu02 | Polyclonal Antibody to Serpin B3 (SERPINB3) | WB; IHC; ICC; IP. |
| MAB372Hu24 | Monoclonal Antibody to Serpin B3 (SERPINB3) | WB; IHC. |
| MAB372Hu22 | Monoclonal Antibody to Serpin B3 (SERPINB3) | WB; IHC; ICC; IP. |
| MAB372Hu21 | Monoclonal Antibody to Serpin B3 (SERPINB3) | WB; IHC; ICC; IP. |
| MAB372Hu23 | Monoclonal Antibody to Serpin B3 (SERPINB3) | WB. |
| SEB372Hu | ELISA Kit for Serpin B3 (SERPINB3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCB372Hu | CLIA Kit for Serpin B3 (SERPINB3) | Chemiluminescent immunoassay for Antigen Detection. |
| LMB372Hu | Magnetic Luminex Assay Kit for Serpin B3 (SERPINB3) ,etc. | Magnetic Luminex Assay for Antigen Detection. |