Skip to product information
1 of 1

Cloud-clone

SKU:WEA754Mu

Wide-range ELISA Kit for Myosin Heavy Chain 1 (MYH1)

Wide-range ELISA Kit for Myosin Heavy Chain 1 (MYH1)

Regular price $616.00 USD
Regular price Sale price $616.00 USD
Sale Sold out
Shipping calculated at checkout.
UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

WEA754Mu

Organism Species

Mus musculus (Mouse).

Sample Type

serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

0.312-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.131ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Wide-range Myosin Heavy Chain 1 (MYH1).
No significant cross-reactivity or interference between Wide-range Myosin Heavy Chain 1 (MYH1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Wide-range Myosin Heavy Chain 1 (MYH1) and the recovery rates were calculated by comparing the measured value to the expected amount of Wide-range Myosin Heavy Chain 1 (MYH1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-93 81
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 83-91 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wide-range Myosin Heavy Chain 1 (MYH1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wide-range Myosin Heavy Chain 1 (MYH1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Wide-range Myosin Heavy Chain 1 (MYH1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 87-101% 89-96% 97-105%
EDTA plasma(n=5) 92-102% 93-101% 92-101% 98-105%
heparin plasma(n=5) 80-104% 94-101% 86-95% 99-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA754Mu01 Recombinant Myosin Heavy Chain 1 (MYH1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA754Mu02 Recombinant Myosin Heavy Chain 1 (MYH1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA754Mu02 Polyclonal Antibody to Myosin Heavy Chain 1 (MYH1) WB; IHC; ICC; IP.
PAA754Mu01 Polyclonal Antibody to Myosin Heavy Chain 1 (MYH1) WB; IHC; ICC; IP.
LAA754Mu81 FITC-Linked Polyclonal Antibody to Myosin Heavy Chain 1 (MYH1) WB; IHC; ICC; IF.
LAA754Mu71 Biotin-Linked Polyclonal Antibody to Myosin Heavy Chain 1 (MYH1) WB; IHC; ICC.
SEA754Mu ELISA Kit for Myosin Heavy Chain 1 (MYH1) Enzyme-linked immunosorbent assay for Antigen Detection.
WEA754Mu Wide-range ELISA Kit for Myosin Heavy Chain 1 (MYH1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA754Mu Magnetic Luminex Assay Kit for Myosin Heavy Chain 1 (MYH1) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSA754Mu01 ELISA Kit DIY Materials for Myosin Heavy Chain 1 (MYH1) Main materials for "Do It (ELISA Kit) Yourself".
View full details