Cloud-clone
SKU:SEC642Mu
ELISA Kit for Moesin (MSN)
ELISA Kit for Moesin (MSN)
Couldn't load pickup availability
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEC642Mu
Organism Species
Mus musculus (Mouse).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
78-5,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 35pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Moesin (MSN).
No significant cross-reactivity or interference between Moesin (MSN) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Moesin (MSN) and the recovery rates were calculated by comparing the measured value to the expected amount of Moesin (MSN) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 98-105 | 101 |
| EDTA plasma(n=5) | 86-94 | 89 |
| heparin plasma(n=5) | 85-99 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Moesin (MSN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Moesin (MSN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Moesin (MSN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 81-101% | 80-91% | 86-97% | 86-101% |
| EDTA plasma(n=5) | 81-98% | 98-105% | 99-105% | 79-101% |
| heparin plasma(n=5) | 80-95% | 92-102% | 99-105% | 92-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
| Standard | 2 | Standard Diluent | 1×20mL |
| Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
| Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
| TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
| Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
| Magazine | Citations |
| PLoS One | Presence in the Pre-Surgical Fine-Needle Aspiration of Potential Thyroid Biomarkers Previously Identified in the Post-Surgical One PubMed: PMC3765839 |
| PLoS One.? | Proteomic Profiles in Acute Respiratory Distress Syndrome Differentiates Survivors from Non-Survivors Pubmed:25290099 |
| Bhargava, Maneesh | Proteomic Studies in Acute Hypoxic Respiratory Failure Handle: 11299 |
| Translational Research | Proteomic analysis of fine-needle aspiration in differential diagnosis of thyroid nodules Pubmed:27172385 |
| Comparative Evaluation of Membrane-Organizing Extension Spike Protein in Gingival Crevicular Fluid in Individuals with and Without Severe Chronic … | |
| Journal of Immunology Research | Moesin Is a Novel Biomarker of Endothelial Injury in Sepsis 33628853 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| PAC642Mu01 | Polyclonal Antibody to Moesin (MSN) | WB; IHC; ICC; IP. |
| SEC642Mu | ELISA Kit for Moesin (MSN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMC642Mu | Magnetic Luminex Assay Kit for Moesin (MSN) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share