Cloud-clone
SKU:LMD198Ra
Magnetic Luminex Assay Kit for Sequestosome 1 (SQSTM1) ,etc.
Magnetic Luminex Assay Kit for Sequestosome 1 (SQSTM1) ,etc.
Couldn't load pickup availability
Product No.
LMD198Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.02-20ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.007 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Sequestosome 1 (SQSTM1) ,etc..
No significant cross-reactivity or interference between Sequestosome 1 (SQSTM1) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Sequestosome 1 (SQSTM1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Sequestosome 1 (SQSTM1) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 98-105 | 102 |
| EDTA plasma(n=5) | 96-104 | 101 |
| heparin plasma(n=5) | 97-105 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sequestosome 1 (SQSTM1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sequestosome 1 (SQSTM1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sequestosome 1 (SQSTM1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 83-99% | 93-102% | 96-105% | 79-96% |
| EDTA plasma(n=5) | 78-103% | 79-91% | 80-103% | 86-93% |
| heparin plasma(n=5) | 88-96% | 82-102% | 79-96% | 91-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:SQSTM1) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| BRIEFINGS IN BIOINFORMATICS | Lysosome activation in peripheral blood mononuclear cells and prognostic significance of circulating LC3B in COVID-19 33620066 |
| BIOMARKERS OF AUTOPHAGY AND ANTIVIRAL ROLE OF PLACENTA FOR PREDICTING PRETERM DELIVERY IN PATIENTS WITH PRETERM DELIVERY?¡ |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| RPD198Ra01 | Recombinant Sequestosome 1 (SQSTM1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAD198Ra01 | Polyclonal Antibody to Sequestosome 1 (SQSTM1) | WB; IHC; ICC; IP. |
| SED198Ra | ELISA Kit for Sequestosome 1 (SQSTM1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMD198Ra | Magnetic Luminex Assay Kit for Sequestosome 1 (SQSTM1) ,etc. | Magnetic Luminex Assay for Antigen Detection. |