Skip to product information
1 of 1

Cloud-clone

SKU:LMA389Mu

Magnetic Luminex Assay Kit for Complement Component 4a (C4a) ,etc.

Magnetic Luminex Assay Kit for Complement Component 4a (C4a) ,etc.

Regular price $778.00 USD
Regular price Sale price $778.00 USD
Sale Sold out
Shipping calculated at checkout.
Detection range
Size
Sensitivity

Product No.

LMA389Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

1.95-2000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.65 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Complement Component 4a (C4a) ,etc..
No significant cross-reactivity or interference between Complement Component 4a (C4a) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Complement Component 4a (C4a) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 4a (C4a) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-103 101
EDTA plasma(n=5) 80-88 85
heparin plasma(n=5) 83-93 87
sodium citrate plasma(n=5) 86-99 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 4a (C4a) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 4a (C4a) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 4a (C4a) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 85-103% 88-102% 78-105%
EDTA plasma(n=5) 78-91% 97-104% 84-104% 88-101%
heparin plasma(n=5) 83-93% 88-96% 79-96% 79-98%
sodium citrate plasma(n=5) 89-96% 92-99% 87-94% 86-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:C4a) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine. 

     

    Magazine Citations
    Journal of Vascular Surgery Circulation levels of acute phase proteins in patients with Takayasu arteritis PubMed: 20100644
    PLoS ONE Identification of Altered Plasma Proteins by Proteomic Study in Valvular Heart Diseases and the Potential Clinical Significance PubMed: PMC3754973
    PLoS One Higher Serum Angiotensinogen Is an Indicator of IgA Vasculitis with Nephritis Revealed by Comparative Proteomes Analysis PubMed: 26098644
    PLoS One Plasma Protein Biomarkers of Hepatocellular Carcinoma in HCV-Infected Alcoholic Patients with Cirrhosis PubMed: 25789864
    Experimental Eye Research Quantitative analysis of hydroxyapatite-binding plasma proteins in genotyped individuals with late-stage age-related macular degeneration Pubmed:29580721
    Diagnostics Systemic Alterations of Immune Response-Related Proteins during Glaucoma Development in the Murine Model DBA/2J Pubmed: 32585848
    Scientific Reports Maternal Serum Proteomic Profiles of Pregnant Women With Type 1 Diabetes 34940989
    Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
    RPA389Mu01 Recombinant Complement Component 4a (C4a) Positive Control; Immunogen; SDS-PAGE; WB.
    RPA389Mu02 Recombinant Complement Component 4a (C4a) Positive Control; Immunogen; SDS-PAGE; WB.
    PAA389Mu02 Polyclonal Antibody to Complement Component 4a (C4a) WB; IHC; ICC; IP.
    PAA389Mu01 Polyclonal Antibody to Complement Component 4a (C4a) WB; IHC
    SEA389Mu ELISA Kit for Complement Component 4a (C4a) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMA389Mu Magnetic Luminex Assay Kit for Complement Component 4a (C4a) ,etc. Magnetic Luminex Assay for Antigen Detection.
    View full details