Skip to product information
1 of 1

Cloud-clone

SKU:LMG374Ra

Magnetic Luminex Assay Kit for ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc.

Magnetic Luminex Assay Kit for ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc.

Regular price $912.00 USD
Regular price Sale price $912.00 USD
Sale Sold out
Shipping calculated at checkout.
Detection range
Size
Sensitivity

Product No.

LMG374Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc..
No significant cross-reactivity or interference between ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-104 99
EDTA plasma(n=5) 93-101 98
heparin plasma(n=5) 80-99 83
sodium citrate plasma(n=5) 85-92 89

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-105% 85-93% 78-92% 85-96%
EDTA plasma(n=5) 79-104% 81-104% 94-101% 81-93%
heparin plasma(n=5) 94-104% 80-94% 91-105% 97-104%
sodium citrate plasma(n=5) 95-102% 99-105% 80-101% 85-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ATP2A2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
The Journal of Heart and Lung Transplantation SERCA2a: A potential non-invasive biomarker of cardiac allograft rejection. pubmed:28750934
researchsquare Value of SERCA2a as a Biomarker for the Identification of Patients With Advanced Heart Failure Requiring Circulatory Support
Journal of Personalized Medicine Value of SERCA2a as a Biomarker for the Identification of Patients with Heart Failure Requiring Circulatory Support 34834474
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
SEG374Ra ELISA Kit for ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG374Ra Magnetic Luminex Assay Kit for ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSG374Ra01 ELISA Kit DIY Materials for ATPase, Ca++ Transporting, Cardiac Muscle, Slow Twitch 2 (ATP2A2) Main materials for "Do It(ELISA Kit) Yourself"
View full details