Cloud-clone
SKU:LMF317Hu
Magnetic Luminex Assay Kit for Carboxypeptidase A4 (CPA4) ,etc.
Magnetic Luminex Assay Kit for Carboxypeptidase A4 (CPA4) ,etc.
Couldn't load pickup availability
Product No.
LMF317Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Carboxypeptidase A4 (CPA4) ,etc..
No significant cross-reactivity or interference between Carboxypeptidase A4 (CPA4) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Carboxypeptidase A4 (CPA4) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Carboxypeptidase A4 (CPA4) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 98-105 | 101 |
| EDTA plasma(n=5) | 88-99 | 93 |
| heparin plasma(n=5) | 88-102 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carboxypeptidase A4 (CPA4) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carboxypeptidase A4 (CPA4) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Carboxypeptidase A4 (CPA4) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 86-93% | 81-99% | 86-93% | 97-105% |
| EDTA plasma(n=5) | 78-94% | 98-105% | 89-96% | 79-99% |
| heparin plasma(n=5) | 90-98% | 84-98% | 94-102% | 86-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:CPA4) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| American Journal of Cancer Research | CPA4 is a promising diagnostic serum biomarker for pancreatic cancer Pubmed:27073726 |
| Journal of Cancer | CPA4 is a Novel Diagnostic and Prognostic Marker for Human Non-Small-Cell Lung Cancer Pubmed:27390594 |
| Oncotarget | Serum carboxypeptidaseA4 levels predict liver metastasis in colorectal carcinoma pubmed:27780921 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPF317Hu01 | Recombinant Carboxypeptidase A4 (CPA4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAF317Hu01 | Polyclonal Antibody to Carboxypeptidase A4 (CPA4) | WB |
| MAF317Hu21 | Monoclonal Antibody to Carboxypeptidase A4 (CPA4) | WB; IHC; ICC; IP. |
| SEF317Hu | ELISA Kit for Carboxypeptidase A4 (CPA4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMF317Hu | Magnetic Luminex Assay Kit for Carboxypeptidase A4 (CPA4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |