Cloud-clone
SKU:LMB443Hu
Magnetic Luminex Assay Kit for Placental Protein 13 (PP13) ,etc.
Magnetic Luminex Assay Kit for Placental Protein 13 (PP13) ,etc.
Couldn't load pickup availability
Product No.
LMB443Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Placental Protein 13 (PP13) ,etc..
No significant cross-reactivity or interference between Placental Protein 13 (PP13) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Placental Protein 13 (PP13) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Placental Protein 13 (PP13) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-101 | 95 |
| EDTA plasma(n=5) | 89-97 | 94 |
| heparin plasma(n=5) | 82-89 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Placental Protein 13 (PP13) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Placental Protein 13 (PP13) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Placental Protein 13 (PP13) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 94-101% | 97-105% | 99-105% | 82-90% |
| EDTA plasma(n=5) | 93-102% | 79-95% | 97-105% | 82-96% |
| heparin plasma(n=5) | 93-102% | 94-103% | 88-96% | 83-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:PP13) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Archives of Gynecology and Obstetrics | Plasma PP13 and urinary GAGs/PGs as early markers of pre-eclampsia Pubmed:27161490 |
| Pathophysiology | Prediction of first-trimester preeclampsia: Relevance of the oxidative stress marker MDA in a combination model with PP-13, PAPP-A and beta-HCG Pubmed:29510888 |
| J Matern Fetal Neonatal Med | Prediction of preeclampsia using first trimester placental protein 13 and uterine artery Doppler Pubmed: 33198548 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB443Hu01 | Recombinant Placental Protein 13 (PP13) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB443Hu01 | Polyclonal Antibody to Placental Protein 13 (PP13) | WB,IHC |
| MAB443Hu22 | Monoclonal Antibody to Placental Protein 13 (PP13) | WB; IHC; ICC; IP. |
| SEB443Hu | ELISA Kit for Placental Protein 13 (PP13) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB443Hu | Magnetic Luminex Assay Kit for Placental Protein 13 (PP13) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share