Magnetic Luminex Assay Kit for Apolipoprotein C3 (APOC3) ,etc.
Magnetic Luminex Assay Kit for Apolipoprotein C3 (APOC3) ,etc.
Couldn't load pickup availability
Product No.
LMB890Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.1-100ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.033 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Apolipoprotein C3 (APOC3) ,etc..
No significant cross-reactivity or interference between Apolipoprotein C3 (APOC3) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Apolipoprotein C3 (APOC3) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Apolipoprotein C3 (APOC3) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 87-95 | 90 |
| EDTA plasma(n=5) | 95-104 | 101 |
| heparin plasma(n=5) | 79-96 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apolipoprotein C3 (APOC3) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apolipoprotein C3 (APOC3) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apolipoprotein C3 (APOC3) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 85-92% | 78-93% | 89-103% | 90-98% |
| EDTA plasma(n=5) | 84-103% | 80-101% | 94-102% | 81-90% |
| heparin plasma(n=5) | 94-103% | 82-94% | 91-98% | 79-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:APOC3) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Atherosclerosis | Up-reCavia (Guinea pig )lation of Hnf1α gene expression in the liver of rats with experimentally induced chronic renal failure – A possible link between circulating PCSK9 and triacylglycerol concentrations Pubmed:26978583 |
| The Journal of Lipid Research | Effects of angiopoietin-like protein 3 deficiency on postprandial lipid and lipoprotein metabolism Pubmed:27040449 |
| Journal of Chromatography A | Application of a new procedure for liquid chromatography/mass spectrometry profiling of plasma amino acid-related metabolites and untargeted shotgun proteomics to identify mechanisms and biomarkers of calcific aortic stenosis S0021967317311858 |
| J Transl Med | Multi-omic signatures of atherogenic dyslipidaemia: pre-clinical target identification and validation in humans 33407555 |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB890Ra01 | Recombinant Apolipoprotein C3 (APOC3) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB890Ra01 | Polyclonal Antibody to Apolipoprotein C3 (APOC3) | WB; IHC; ICC; IP. |
| LAB890Ra71 | Biotin-Linked Polyclonal Antibody to Apolipoprotein C3 (APOC3) | WB; IHC; ICC. |
| LAB890Ra81 | FITC-Linked Polyclonal Antibody to Apolipoprotein C3 (APOC3) | WB; IHC; ICC; IF. |
| MAB890Ra21 | Monoclonal Antibody to Apolipoprotein C3 (APOC3) | WB; IHC; ICC; IP. |
| SEB890Ra | ELISA Kit for Apolipoprotein C3 (APOC3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB890Ra | Magnetic Luminex Assay Kit for Apolipoprotein C3 (APOC3) ,etc. | Magnetic Luminex Assay for Antigen Detection. |