Cloud-clone
SKU:LMD984Ge
Magnetic Luminex Assay Kit for Homocysteine (HCy) ,etc.
Magnetic Luminex Assay Kit for Homocysteine (HCy) ,etc.
Couldn't load pickup availability
Product No.
LMD984Ge
Organism Species
Pan-species (General).
Sample Type
Serum, plasma and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
7.81-8000ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 2.603 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Homocysteine (HCy) ,etc..
No significant cross-reactivity or interference between Homocysteine (HCy) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Homocysteine (HCy) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Homocysteine (HCy) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-93 | 84 |
| EDTA plasma(n=5) | 78-103 | 96 |
| heparin plasma(n=5) | 87-94 | 91 |
| sodium citrate plasma(n=5) | 78-93 | 81 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Homocysteine (HCy) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Homocysteine (HCy) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Homocysteine (HCy) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 87-94% | 99-105% | 78-101% | 91-99% |
| EDTA plasma(n=5) | 84-98% | 82-90% | 92-101% | 89-98% |
| heparin plasma(n=5) | 85-98% | 96-103% | 84-97% | 85-99% |
| sodium citrate plasma(n=5) | 97-105% | 85-101% | 99-105% | 83-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:HCy) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Journal of Developmental Origins of Health and Disease | Maternal low-quality protein diet exerts sex-specific effects on plasma amino acid profile and alters hepatic expression of methyltransferases in adult rat offspring Pubmed:29582727 |
| The Scientific Journal of Al-Azhar Medical Faculty, Girls | Homocysteinemia in relation to anemia in hypothyroid patients Doi: 10.4103/sjamf.sjamf_31_18 |
| Science of The Total Environment | Organochlorine pesticides exposure may disturb homocysteine metabolism in pregnant women Pubmed: 31787282 |
| AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH | Baicalin rescues hyperglycemia-induced neural tube defects via targeting on retinoic acid signaling Pubmed: 32774702 |
| Journal of Diabetes Research | Changes and Risk Factors of Skeletal Muscle Mass and Strength in Patients with Type 2 Diabetes over 60 Years Old: A Cross-Sectional Study from China |
| Journal of Advances in Medical and Pharmaceutical Sciences | Homocysteinaemia in Heart Failure Patients in North Eastern Nigeria |
| Obstetrik ve Neonatoloji T?p Dergisi | KARD?YOVASK¨¹LER S?STEM HASTALIKLARINDA R?SK FAKT?R¨¹ OLAN H?PERHOMOS?STE?NEM?'N?N POL?K?ST?K OVER SENDROMUNDAK? YER? |
| Frontiers in Nutrition | Folate, Vitamin B12, and Homocysteine Levels in Women With Neural Tube Defect-Affected Pregnancy in Addis Ababa, Ethiopia Pubmed:35464038 |
| Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
| CPD984Ge11 | BSA Conjugated Homocysteine (HCy) | Immunogen; SDS-PAGE; WB. |
| CPD984Ge21 | OVA Conjugated Homocysteine (HCy) | Immunogen; SDS-PAGE; WB. |
| PAD984Ge01 | Polyclonal Antibody to Homocysteine (HCy) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
| MED984Ge | Mini Samples ELISA Kit for Homocysteine (HCy) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CED984Ge | ELISA Kit for Homocysteine (HCy) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMD984Ge | Magnetic Luminex Assay Kit for Homocysteine (HCy) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
| KSD984Ge11 | ELISA Kit DIY Materials for Homocysteine (HCy) | Main materials for "Do It (ELISA Kit) Yourself". |