SKU:LMA220Ca
Magnetic Luminex Assay Kit for Adrenomedullin (ADM) ,etc.
Magnetic Luminex Assay Kit for Adrenomedullin (ADM) ,etc.
Couldn't load pickup availability
Product No.
LMA220Ca
Organism Species
Canis familiaris; Canine (Dog).
Sample Type
Serum, plasma and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Adrenomedullin (ADM) ,etc..
No significant cross-reactivity or interference between Adrenomedullin (ADM) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Adrenomedullin (ADM) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Adrenomedullin (ADM) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 94-105 | 99 |
| EDTA plasma(n=5) | 84-96 | 88 |
| heparin plasma(n=5) | 95-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adrenomedullin (ADM) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adrenomedullin (ADM) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adrenomedullin (ADM) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 87-101% | 96-103% | 97-104% | 83-94% |
| EDTA plasma(n=5) | 80-99% | 87-103% | 78-103% | 88-104% |
| heparin plasma(n=5) | 91-98% | 78-96% | 93-101% | 90-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:ADM) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Journal of Periodontal Research | Gingival crevicular fluid adrenomedullin level in individuals with and without diabetes mellitus type 2 Wiley: Source |
| J Periodontal Res. | Comparison of peri-implant crevicular fluid levels of adrenomedullin and human beta defensins 1 and 2 from mandibular implants with different implant stability quotient levels in nonsmoker patients Pubmed: 23898869 |
| Journal of Biosciences | Short-term hypoxia/reoxygenation activates the angiogenic pathway in rat caudate putamen. Pubmed: 23660671 |
| Journal of Translational Medicine | DNA methylation patterns in newborns exposed to tobacco in utero Pubmed:25623364 |
| Pediatric Hematology and Oncology | Adrenomedullin—A New Marker in Febrile Neutropenia: Comparison With CRP and Procalcitonin PubMed: 26271020 |
| Biogerontology. | Angiogenesis is VEGF-independent in the aged striatum of male rats exposed to acute hypoxia. pubmed:28501895 |
| Journal of Clinical Investigation | Adrenomedullin and Galanin Responses to Orthostasis in Older Persons pubmed:28796366 |
| Clinical Pathology and Medical Laboratory | ADRENOMEDULIN DI KARSINOMA PAYUDARA DENGAN METASTASIS : |
| Phytomedicine | Composition and cardioprotective effects of Primula veris L. solid herbal extract in experimental chronic heart failure Doi: 10.1016/j.phymed.2018.09.015 |
| Biomedical Journal of Scientific & Technical Research | Anti-Inflammatory and Pro-Inflammatory Neuropeptides in Dilative Cardiomyopathy are there Relations to Psychophysical Stress? |
| 博士论文 | Clinical and experimental investigation of the nervous system of neonatal foals. Neuroendocrin transition from foetal consciousness to perinatal life |
| Biology | Hemodynamic Responses in Lower Limb Lymphedema Patients Undergoing Physical Therapy 34356497 |
| Catalog No. | Related products for research use of Canis familiaris; Canine (Dog) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA220Ca01 | Recombinant Adrenomedullin (ADM) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA220Ca01 | Polyclonal Antibody to Adrenomedullin (ADM) | WB; IHC; ICC; IP. |
| LAA220Ca71 | Biotin-Linked Polyclonal Antibody to Adrenomedullin (ADM) | WB; IHC; ICC. |
| MAA220Ca21 | Monoclonal Antibody to Adrenomedullin (ADM) | WB; IHC; ICC; IP. |
| CEA220Ca | ELISA Kit for Adrenomedullin (ADM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA220Ca | Magnetic Luminex Assay Kit for Adrenomedullin (ADM) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share