Cloud-clone
SKU:LMC150Mu
Magnetic Luminex Assay Kit for Collagen Type VI Alpha 1 (COL6a1) ,etc.
Magnetic Luminex Assay Kit for Collagen Type VI Alpha 1 (COL6a1) ,etc.
Couldn't load pickup availability
Product No.
LMC150Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Serum, plasma and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.04-40ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.013 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Collagen Type VI Alpha 1 (COL6a1) ,etc..
No significant cross-reactivity or interference between Collagen Type VI Alpha 1 (COL6a1) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Collagen Type VI Alpha 1 (COL6a1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Collagen Type VI Alpha 1 (COL6a1) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 81-101 | 91 |
| EDTA plasma(n=5) | 91-101 | 97 |
| heparin plasma(n=5) | 80-95 | 81 |
| sodium citrate plasma(n=5) | 99-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Collagen Type VI Alpha 1 (COL6a1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Collagen Type VI Alpha 1 (COL6a1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Collagen Type VI Alpha 1 (COL6a1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 89-97% | 79-93% | 86-105% | 83-98% |
| EDTA plasma(n=5) | 86-94% | 79-98% | 97-105% | 81-98% |
| heparin plasma(n=5) | 78-89% | 79-101% | 93-102% | 80-89% |
| sodium citrate plasma(n=5) | 95-104% | 94-103% | 96-105% | 89-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:COL6a1) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Molecular & Cellular Proteomics | Integrated Proteomic Profiling of Cell Line Conditioned Media and Pancreatic Juice for the Identification of Pancreatic Cancer Biomarkers PubMed: PMC3205865 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| APC150Mu03 | Active Collagen Type VI Alpha 1 (COL6a1) | Cell culture; Activity Assays. |
| RPC150Mu02 | Recombinant Collagen Type VI Alpha 1 (COL6a1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPC150Mu03 | Recombinant Collagen Type VI Alpha 1 (COL6a1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPC150Mu01 | Recombinant Collagen Type VI Alpha 1 (COL6a1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| APC150Mu02 | Active Collagen Type VI Alpha 1 (COL6a1) | Cell culture; Activity Assays. |
| PAC150Mu01 | Polyclonal Antibody to Collagen Type VI Alpha 1 (COL6a1) | WB; IHC; ICC; IP. |
| PAC150Mu03 | Polyclonal Antibody to Collagen Type VI Alpha 1 (COL6a1) | WB; IHC; ICC; IP. |
| PAC150Mu02 | Polyclonal Antibody to Collagen Type VI Alpha 1 (COL6a1) | WB; IHC; ICC; IP. |
| LAC150Mu71 | Biotin-Linked Polyclonal Antibody to Collagen Type VI Alpha 1 (COL6a1) | WB; IHC; ICC. |
| SEC150Mu | ELISA Kit for Collagen Type VI Alpha 1 (COL6a1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMC150Mu | Magnetic Luminex Assay Kit for Collagen Type VI Alpha 1 (COL6a1) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share