Cloud-clone
SKU:LMN251Hu
Magnetic Luminex Assay Kit for Adropin (AD) ,etc.
Magnetic Luminex Assay Kit for Adropin (AD) ,etc.
Couldn't load pickup availability
Product No.
LMN251Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
1.95-2000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.65 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Adropin (AD) ,etc..
No significant cross-reactivity or interference between Adropin (AD) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Adropin (AD) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Adropin (AD) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 87-95 | 91 |
| EDTA plasma(n=5) | 98-105 | 101 |
| heparin plasma(n=5) | 92-101 | 95 |
| sodium citrate plasma(n=5) | 92-101 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adropin (AD) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adropin (AD) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adropin (AD) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 84-102% | 79-97% | 83-102% | 91-99% |
| EDTA plasma(n=5) | 83-91% | 83-95% | 82-97% | 94-105% |
| heparin plasma(n=5) | 79-98% | 95-105% | 82-94% | 85-97% |
| sodium citrate plasma(n=5) | 85-95% | 95-102% | 94-101% | 89-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:AD) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Pregnancy Hypertens. | Alteration of serum adropin level in preeclampsia. pubmed:28501281 |
| Frontiers in Molecular Neuroscience | Adropin Is a Key Mediator of Hypoxia Induced Anti-Dipsogenic Effects via TRPV4-CamKK-AMPK Signaling in the Circumventricular Organs of Rats. pubmed:28473751 |
| Preprints | Afamin and Adropin in Patients with Alcohol-Induced Liver Cirrhosis manuscript:201803.0258 |
| Probiotics and Antimicrobial Proteins | Effects of Probiotic Yogurt on Serum Omentin-1, Adropin, and Nesfatin-1 Concentrations in Overweight and Obese Participants Under Low-Calorie Diet Pubmed: 30232744 |
| Probiotics and Antimicrobial Proteins | Mitra Zarrati, Mahsa Raji Lahiji, Eisa Salehi, Bahareh Yazdani, Elham Razmpoosh, Raheleh Shokouhi Shoormasti & Farzad Shidfar Pubmed: 30232744 |
| Pediatr Diabetes | Adropin and apelin‐12 efficiently predict metabolic syndrome in obese children Pubmed: 32749012 |
| European Journal of Therapeutics | Effect of Peri-Implant Disease on Adropin Levels: A Cross-Sectional Pilot Study |
| Horm Mol Biol Clin Investig | Effects of eight weeks exercise training on serum levels of adropin in male volleyball players 33794077 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPN251Hu01 | Recombinant Adropin (AD) | Positive Control; Immunogen; SDS-PAGE; WB. |
| CPN251Hu21 | OVA Conjugated Adropin (AD) | Immunogen; SDS-PAGE; WB. |
| PAN251Hu01 | Polyclonal Antibody to Adropin (AD) | WB; IHC; ICC; IP. |
| MAN251Hu21 | Monoclonal Antibody to Adropin (AD) | WB; IHC; ICC; IP. |
| SEN251Hu | ELISA Kit for Adropin (AD) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| HEN251Hu | High Sensitive ELISA Kit for Adropin (AD) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CEN251Hu | ELISA Kit for Adropin (AD) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMN251Hu | Magnetic Luminex Assay Kit for Adropin (AD) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share