Cloud-clone
SKU:LMA424Mu
Magnetic Luminex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc.
Magnetic Luminex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc.
Couldn't load pickup availability
Product No.
LMA424Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.
Specificity
This assay has high sensitivity and excellent specificity for detection of Octamer Binding Transcription Factor 4 (OCT4) ,etc..
No significant cross-reactivity or interference between Octamer Binding Transcription Factor 4 (OCT4) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Octamer Binding Transcription Factor 4 (OCT4) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Octamer Binding Transcription Factor 4 (OCT4) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 93-101 | 97 |
| EDTA plasma(n=5) | 81-90 | 85 |
| heparin plasma(n=5) | 89-97 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Octamer Binding Transcription Factor 4 (OCT4) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 79-102% | 89-103% | 87-95% | 80-91% |
| EDTA plasma(n=5) | 96-104% | 96-105% | 96-105% | 98-105% |
| heparin plasma(n=5) | 87-97% | 88-97% | 83-98% | 98-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:OCT4) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Analytical Methods | A universal glucometer-based biosensor for portable and quantitative detection of transcription factors Rsc: Source |
| Oncology Letters | Upregulation of stem cell markers ALDH1A1 and OCT4 as potential biomarkers for the early detection of cervical carcinoma Doi: 10.3892/ol.2018.9381 |
| Stem Cell Research | Generation of two induced pluripotent stem cell lines NCCSi005A and NCCSi006A from CD4+ T cells of healthy individuals of Indian origin |
| 博士论文 | Experimental and Modeling Framework for the Production of Cell and Protein-Based Biopharmaceutical Products |
| Stem Cell Research | Generation and characterization of three clones (NCCSi007A, NCCSi007B and NCCSi007C) of an integration free induced Pluripotent Stem Cell line from a … Pubmed: 31862609 |
| J Biochem Mol Toxicol | Studies on male gonadal toxicity of bisphenol A in diabetic rats: An example of exacerbation effect Pubmed:35187753 |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA424Mu02 | Recombinant Octamer Binding Transcription Factor 4 (OCT4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA424Mu01 | Recombinant Octamer Binding Transcription Factor 4 (OCT4) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA424Mu02 | Polyclonal Antibody to Octamer Binding Transcription Factor 4 (OCT4) | WB; IHC; ICC; IP. |
| PAA424Mu01 | Polyclonal Antibody to Octamer Binding Transcription Factor 4 (OCT4) | WB; IHC; ICC; IP. |
| SEA424Mu | ELISA Kit for Octamer Binding Transcription Factor 4 (OCT4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA424Mu | Magnetic Luminex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share