SKU:LMA670Ra

Magnetic Luminex Assay Kit for Homing Associated Cell Adhesion Molecule (HCAM) ,etc.

Magnetic Luminex Assay Kit for Homing Associated Cell Adhesion Molecule (HCAM) ,etc.

Regular price $821.00 USD
Regular price Sale price $821.00 USD
Sale Sold out
Shipping calculated at checkout.
Detection range
Size
Sensitivity

Product No.

LMA670Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Homing Associated Cell Adhesion Molecule (HCAM) ,etc..
No significant cross-reactivity or interference between Homing Associated Cell Adhesion Molecule (HCAM) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Homing Associated Cell Adhesion Molecule (HCAM) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Homing Associated Cell Adhesion Molecule (HCAM) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-99 94
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 88-105 101
sodium citrate plasma(n=5) 79-90 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Homing Associated Cell Adhesion Molecule (HCAM) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Homing Associated Cell Adhesion Molecule (HCAM) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Homing Associated Cell Adhesion Molecule (HCAM) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-96% 97-104% 99-105% 95-103%
EDTA plasma(n=5) 86-97% 89-97% 83-99% 84-91%
heparin plasma(n=5) 80-102% 89-96% 81-101% 82-95%
sodium citrate plasma(n=5) 88-96% 84-103% 98-105% 86-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:HCAM) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Cancers Predictive Value of Soluble PD-1, PD-L1, VEGFA, CD40 Ligand and CD44 for Nivolumab Therapy in Advanced Non-Small Cell Lung Cancer: A Case-Control Study Pubmed: 32085544
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA670Ra01 Recombinant Homing Associated Cell Adhesion Molecule (HCAM) Positive Control; Immunogen; SDS-PAGE; WB.
PAA670Ra01 Polyclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC
MAA670Ra21 Monoclonal Antibody to Homing Associated Cell Adhesion Molecule (HCAM) WB; IHC; ICC; IP.
SEA670Ra ELISA Kit for Homing Associated Cell Adhesion Molecule (HCAM) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA670Ra Magnetic Luminex Assay Kit for Homing Associated Cell Adhesion Molecule (HCAM) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSA670Ra01 ELISA Kit DIY Materials for Homing Associated Cell Adhesion Molecule (HCAM) Main materials for "Do It(ELISA Kit) Yourself"
View full details