Cloud-clone
SKU:LMA132Hu
Magnetic Luminex Assay Kit for Adiponectin Receptor 2 (ADIPOR2) ,etc.
Magnetic Luminex Assay Kit for Adiponectin Receptor 2 (ADIPOR2) ,etc.
Couldn't load pickup availability
Product No.
LMA132Hu
Organism Species
Homo sapiens (Human).
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.05-50ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.017 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.
Specificity
This assay has high sensitivity and excellent specificity for detection of Adiponectin Receptor 2 (ADIPOR2) ,etc..
No significant cross-reactivity or interference between Adiponectin Receptor 2 (ADIPOR2) ,etc. and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adiponectin Receptor 2 (ADIPOR2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adiponectin Receptor 2 (ADIPOR2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:ADIPOR2) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| PLoS One | Topiramate-Induced Modulation of Hepatic Molecular Mechanisms: An Aspect for Its Anti-Insulin Resistant Effect PubMed: 22649556 |
| Applied Physiology, Nutrition, and Metabolism | Estimation of ellagic acid and/or repaglinide effects on insulin signaling, oxidative stress, andinflammatory mediators of liver, pancreas, adipose tissue, and brain in insulin resistant/type 2 diabetic rats. pubmed:28092161 |
| Cancer Cell Research | Effects of hyperbaric oxygen on adiponect and glucose transporter 4 expression in type 2 diabetic rats Pdf:20180601.pdf |
| Animal Reproduction Science | Abundance of adiponectin mRNA transcript in the buffalo corpus luteum during the estrous cycle and effects on progesterone secretion in vitro |
| Reproduction in Domestic Animals | Expression and localization of adiponectin and its receptors in ovarian follicles during different stages of development and the modulatory effect of adiponectin on … |
| Pediatric Gastroenterology, Hepatology & Nutrition | Role of Soluble Adiponectin Receptor 2 in Non-Alcoholic Fatty Liver Disease in Children Pubmed: 31555572 |
| Veterinary Sciences | Adiponectin Influences FGF2 in the Developing Porcine Corpus Luteum Pubmed:35202330 |
Share
