Cloud-clone
SKU:LMA634Ra
Magnetic Luminex Assay Kit for Trypsinogen Activation Peptide (TAP) ,etc.
Magnetic Luminex Assay Kit for Trypsinogen Activation Peptide (TAP) ,etc.
Couldn't load pickup availability
Product No.
LMA634Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
9.77-10000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 3.257 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.
Specificity
This assay has high sensitivity and excellent specificity for detection of Trypsinogen Activation Peptide (TAP) ,etc..
No significant cross-reactivity or interference between Trypsinogen Activation Peptide (TAP) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Trypsinogen Activation Peptide (TAP) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Trypsinogen Activation Peptide (TAP) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 90-104 | 96 |
| EDTA plasma(n=5) | 88-95 | 91 |
| heparin plasma(n=5) | 98-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Trypsinogen Activation Peptide (TAP) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Trypsinogen Activation Peptide (TAP) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Trypsinogen Activation Peptide (TAP) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 94-101% | 80-94% | 80-105% | 87-95% |
| EDTA plasma(n=5) | 84-94% | 93-102% | 78-102% | 85-99% |
| heparin plasma(n=5) | 92-101% | 88-97% | 79-101% | 96-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:TAP) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Diabetologia | Diabetes aggravates acute pancreatitis and inhibits pancreas regeneration in mice SpringerLink: x4l01435t34452jr |
| Molecular Biology Reports | Prior peritoneal lavage with hot 0.9% saline induces HSP70 expression and protects against cerulein-induced acute pancreatitis in rats Pubmed: 23096089 |
| Journal of the Pancreas | Case report of mannose-binding lectin (MBL) deficiency and postoperative sepsis and coagulopathy in a patient following total pancreatectomy for chronic pancreatitis. Pubmed:25262717 |
| Journal of Gastroenterology | A small molecule inhibitor of NFκB blocks ER stress and the NLRP3 inflammasome and prevents progression of pancreatitis pubmed:27418337 |
| Indian Journal of Pharmaceutical Sciences | Effects of Calcium Channel Blockers on Trypsinogen Activation and Severity of Cerulein-induced Acute Pancreatitis in Rats IJPS:Source |
| Tropical Journal of Pharmaceutical Research | Investigation of non-pharmaceutical cures for acute pancreatitis induced by cerulein in rats |
| Pancreas | The Regulatory Effect of the Kinase Inhibitor PD98059 on Autophagic Flux During Trypsinogen Activation in Pancreatic Acinar Cells Pubmed: 32011537 |
| Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
| CPA634Ra11 | BSA Conjugated Trypsinogen Activation Peptide (TAP) | Immunogen; SDS-PAGE; WB. |
| CPA634Ra21 | OVA Conjugated Trypsinogen Activation Peptide (TAP) | Immunogen; SDS-PAGE; WB. |
| CEA634Ra | ELISA Kit for Trypsinogen Activation Peptide (TAP) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA634Ra | Magnetic Luminex Assay Kit for Trypsinogen Activation Peptide (TAP) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
| KSA634Ra11 | ELISA Kit DIY Materials for Trypsinogen Activation Peptide (TAP) | Main materials for "Do It (ELISA Kit) Yourself". |
Share