Cloud-clone
SKU:LMB331Hu
Magnetic Luminex Assay Kit for Involucrin (INV) ,etc.
Magnetic Luminex Assay Kit for Involucrin (INV) ,etc.
Couldn't load pickup availability
Product No.
LMB331Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.02-20ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.007 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.
Specificity
This assay has high sensitivity and excellent specificity for detection of Involucrin (INV) ,etc..
No significant cross-reactivity or interference between Involucrin (INV) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Involucrin (INV) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Involucrin (INV) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 80-91 | 84 |
| EDTA plasma(n=5) | 98-105 | 102 |
| heparin plasma(n=5) | 89-103 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Involucrin (INV) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Involucrin (INV) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Involucrin (INV) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 90-99% | 78-91% | 93-105% | 85-95% |
| EDTA plasma(n=5) | 97-104% | 78-95% | 86-95% | 89-99% |
| heparin plasma(n=5) | 84-97% | 98-105% | 91-101% | 93-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:INV) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| ?Inflammation & Allergy-Drug Targets | Neuromodulatory and Anti-Inflammatory Ingredient for Sensitive Skin: In Vitro Assessment Pubmed:24931812 |
| PLoS One | Protective Effects of Triphala on Dermal Fibroblasts and Human Keratinocytes Pubmed:26731545 |
| Journal of food biochemistry | In vitro anti-inflammatory and skin protective properties of extract comprising ceramides from de-oiled rice bran doi:10.1111 |
| Journal of Cosmet Dermatol. | Ultraviolet A photosensitivity profile of dexchlorpheniramine maleate and promethazine-based creams: Anti-inflammatory,antihistaminic, and skin barrier protection properties DOI: 10.1111/jocd.12349 |
| European Journal of Pharmacology | Imiquimod-induced psoriasis-like inflammation in differentiated Human keratinocytes: Its evaluation using curcumin. pubmed:28736282 |
| Journal of Traditional and Complementary Medicine | In vitro anti-inflammatory and skin protective properties of Virgin coconut oil 10.1016:j.jtcme.2017.06.012 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| EPB331Hu61 | Eukaryotic Involucrin (INV) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB331Hu01 | Recombinant Involucrin (INV) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB331Hu01 | Polyclonal Antibody to Involucrin (INV) | WB; IHC; ICC; IP. |
| MAB331Hu22 | Monoclonal Antibody to Involucrin (INV) | WB; IHC; ICC; IP. |
| SEB331Hu | ELISA Kit for Involucrin (INV) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB331Hu | Magnetic Luminex Assay Kit for Involucrin (INV) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share