Skip to product information
1 of 1

Cloud-clone

SKU:LMB452Ge

Magnetic Luminex Assay Kit for Lipoxin A4 (LXA4) ,etc.

Magnetic Luminex Assay Kit for Lipoxin A4 (LXA4) ,etc.

Regular price $970.00 USD
Regular price Sale price $970.00 USD
Sale Sold out
Shipping calculated at checkout.
Detection range
Size
Sensitivity

Product No.

LMB452Ge

Organism Species

Pan-species (General).

Sample Type

Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

39.06-40000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 13.02 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Lipoxin A4 (LXA4) ,etc..
No significant cross-reactivity or interference between Lipoxin A4 (LXA4) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Lipoxin A4 (LXA4) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Lipoxin A4 (LXA4) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-104 99
EDTA plasma(n=5) 84-98 92
heparin plasma(n=5) 81-101 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lipoxin A4 (LXA4) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lipoxin A4 (LXA4) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lipoxin A4 (LXA4) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-104% 91-105% 82-89% 96-104%
EDTA plasma(n=5) 84-93% 83-96% 84-103% 98-105%
heparin plasma(n=5) 82-99% 83-98% 98-105% 91-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LXA4) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

     

    Magazine Citations
    Neurotoxicology Redox modulation of cellular stress response and lipoxin A4 expression by Coriolus versicolor in rat brain: Relevance to Alzheimer&#039;s disease pathogenesis PubMed: 26433056
    Immunity & Ageing Redox modulation of cellular stress response and lipoxin A4 expression by Hericium Erinaceus in rat brain: relevance to Alzheimer's disease pathogenesis. pubmed:27398086
    BMC cardiovascular disorders Acute coronary syndrome and acute kidney injury: role of inflammation in worsening renal function pubmed:28747177
    Liver transplantation  CDP‐choline protects liver from ischemia/reperfusion injury preserving mitochondrial function and reducing oxidative stress Pubmed:29679463
    Journal of Immunology Leukocyte CD300a Contributes to the Resolution of Murine Allergic Inflammation Pubmed: 30315138
    Experimental and Therapeutic Medicine Dynamic changes and clinical significance of LXA4 in the perioperative period of cardiopulmonary bypass
    Biochem Genet Lipoxin A4-Mediated p38 MAPK Signaling Pathway Protects Mice Against Collagen-Induced Arthritis 33221976
    The mimetic peptide Ac2-26 of annexin A1 attenuates inflammation and apoptosis in sepsis-induced acute kidney injury
    Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
    CEB452Ge ELISA Kit for Lipoxin A4 (LXA4) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMB452Ge Magnetic Luminex Assay Kit for Lipoxin A4 (LXA4) ,etc. Magnetic Luminex Assay for Antigen Detection.
    View full details