Magnetic Luminex Assay Kit for Cholesteryl Ester Transfer Protein (CETP) ,etc.
Magnetic Luminex Assay Kit for Cholesteryl Ester Transfer Protein (CETP) ,etc.
Couldn't load pickup availability
Product No.
LMA814Rb
Organism Species
Oryctolagus cuniculus (Rabbit).
Sample Type
serum, plasma and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
2.93-3000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.977 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Cholesteryl Ester Transfer Protein (CETP) ,etc..
No significant cross-reactivity or interference between Cholesteryl Ester Transfer Protein (CETP) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Cholesteryl Ester Transfer Protein (CETP) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Cholesteryl Ester Transfer Protein (CETP) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 90-97 | 93 |
| EDTA plasma(n=5) | 79-94 | 84 |
| heparin plasma(n=5) | 82-101 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cholesteryl Ester Transfer Protein (CETP) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cholesteryl Ester Transfer Protein (CETP) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cholesteryl Ester Transfer Protein (CETP) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 90-97% | 78-90% | 79-93% | 80-91% |
| EDTA plasma(n=5) | 90-101% | 98-105% | 96-103% | 82-99% |
| heparin plasma(n=5) | 78-105% | 78-102% | 83-95% | 84-92% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:CETP) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Neurotoxicology. | 27-Hydroxycholesterol regulates cholesterol synthesis and transport in C6 glioma cells. pubmed:28167099 |
| Nutrition | A baru almond-enriched diet reduces abdominal adiposity and improves HDL concentrations: A randomized, placebo-controlled trial Pubmed:30086484 |
| Scientific Reports | CETP genetic variant rs1800777 (allele A) is associated with abnormally low HDL-C levels and increased risk of AKI during sepsis Pubmed: 30425299 |
| Nutrition | A baru almond└ enriched diet reduces abdominal adiposity and improves high-density lipoprotein concentrations: a randomized, placebo-controlled trial Pubmed: 30086484 |
| Laboratory medicine | Association of Serum Cholesterol Ester Transfer Protein Levels with Taq IB Polymorphism in Acute Coronary Syndrome Pubmed: 31504738 |
| Catalog No. | Related products for research use of Oryctolagus cuniculus (Rabbit) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA814Rb01 | Recombinant Cholesteryl Ester Transfer Protein (CETP) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA814Rb02 | Recombinant Cholesteryl Ester Transfer Protein (CETP) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA814Rb51 | Polyclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) | WB; IHC; ICC; IP. |
| PAA814Rb52 | Polyclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) | WB; IHC; ICC; IP. |
| SEA814Rb | ELISA Kit for Cholesteryl Ester Transfer Protein (CETP) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA814Rb | Magnetic Luminex Assay Kit for Cholesteryl Ester Transfer Protein (CETP) ,etc. | Magnetic Luminex Assay for Antigen Detection. |