Cloud-clone
SKU:LMH776Hu
Magnetic Luminex Assay Kit for Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc.
Magnetic Luminex Assay Kit for Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc.
Couldn't load pickup availability
Product No.
LMH776Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.02-25ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.007 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.
Specificity
This assay has high sensitivity and excellent specificity for detection of Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc..
No significant cross-reactivity or interference between Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 89-97 | 93 |
| EDTA plasma(n=5) | 92-105 | 95 |
| heparin plasma(n=5) | 94-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inter Alpha-Globulin Inhibitor H4 (ITIH4) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 84-91% | 93-101% | 99-105% | 93-104% |
| EDTA plasma(n=5) | 90-99% | 91-99% | 90-102% | 88-97% |
| heparin plasma(n=5) | 83-101% | 92-101% | 92-105% | 96-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:ITIH4) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Toxicology Letters | Biomarkers for methotrexate-induced liver injury: urinary protein profiling of psoriasis patients. Pubmed: 23830989 |
| International Journal of Medical Microbiology | Proteomic demonstration of the recurrent presence of inter-alpha-inhibitor H4 heavy-chain during aspergillosis induced in an animal model Pubmed:24360996 |
| Cancer Research and Treatment | Inter-alpha Inhibitor H4 as a Potential Biomarker Predicting the Treatment Outcomes in Patients with Hepatocellular Carcinoma pubmed:28724284 |
| Diagnostics | Systemic Alterations of Immune Response-Related Proteins during Glaucoma Development in the Murine Model DBA/2J Pubmed: 32585848 |
| Liver Cancer | Biomarkers for locally advanced hepatocellular carcinoma patients treated with liver-directed combined radiotherapy |
Share