Cloud-clone
SKU:LMB983Mu
Magnetic Luminex Assay Kit for Tau Protein (MAPT) ,etc.
Magnetic Luminex Assay Kit for Tau Protein (MAPT) ,etc.
Couldn't load pickup availability
Product No.
LMB983Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Tau Protein (MAPT) ,etc..
No significant cross-reactivity or interference between Tau Protein (MAPT) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Tau Protein (MAPT) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Tau Protein (MAPT) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 82-89 | 85 |
| EDTA plasma(n=5) | 85-95 | 90 |
| heparin plasma(n=5) | 86-95 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tau Protein (MAPT) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tau Protein (MAPT) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tau Protein (MAPT) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 85-101% | 78-93% | 83-91% | 89-97% |
| EDTA plasma(n=5) | 79-101% | 95-103% | 88-99% | 78-92% |
| heparin plasma(n=5) | 78-102% | 83-96% | 84-93% | 89-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:MAPT) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Eur Rev Med Pharmacol Sci. | Effect of etanercept and lithium chloride on preventing secondary tissue damage in rats with experimental diffuse severe brain injury Pubmed:24452937 |
| Pediatria i Medycyna Rodzinna | Wpływ omdlenia u młodocianych na stężenie białka tau w surowicy krwi b09f7df8-1e7d-4665-a2a5-bf54dae0cfe9 |
| Acta Angiologica | Serum microtubule associated protein tau and myelin basic protein as the potential markers of brain ischaemia-reperfusion injury in patients undergoing carotid endarterectomy AA.2016.0008 |
| Journal of physiology and pharmacology | THE PRESENCE OF TAU PROTEIN IN BLOOD AS A POTENTIAL PROGNOSTIC FACTOR IN STROKE PATIENTS pubmed:28011949 |
| Acta Angiol | Serum microtubule associated protein tau and myelin basic protein as the potential markers of brain ischaemia-reperfusion injury in patients undergoing carotid endarterectomy AA.2016.0008 |
| Frontiers in Aging Neuroscience | Differential hyperphosphorylation of tau-S199,-T231 and-S396 in organotypic brain slices of Alzheimer mice. A model to study early tau hyperphosphorylation using … Pubmed:29725295 |
| Scientific Reports | The potential role of serum tau protein (MAPT), neuronal cell adhesion molecule (NrCAM) and neprilysin (NEP) in neurodegenerative disorders development in … |
| Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB983Mu02 | Recombinant Tau Protein (MAPT) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB983Mu01 | Recombinant Tau Protein (MAPT) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB983Mu01 | Polyclonal Antibody to Tau Protein (MAPT) | WB; IHC; ICC; IP. |
| PAB983Mu02 | Polyclonal Antibody to Tau Protein (MAPT) | WB; IHC; ICC; IP. |
| MEB983Mu | Mini Samples ELISA Kit for Tau Protein (MAPT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SEB983Mu | ELISA Kit for Tau Protein (MAPT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| HEB983Mu | High Sensitive ELISA Kit for Tau Protein (MAPT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB983Mu | Magnetic Luminex Assay Kit for Tau Protein (MAPT) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
| KSB983Mu01 | ELISA Kit DIY Materials for Tau Protein (MAPT) | Main materials for "Do It (ELISA Kit) Yourself". |