Product No.
LMB516Hu
Organism Species
Homo sapiens (Human).
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Prominin 1 (PROM1) ,etc..
No significant cross-reactivity or interference between Prominin 1 (PROM1) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Prominin 1 (PROM1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Prominin 1 (PROM1) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 85-97 | 91 |
| EDTA plasma(n=5) | 85-103 | 88 |
| heparin plasma(n=5) | 98-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Prominin 1 (PROM1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Prominin 1 (PROM1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Prominin 1 (PROM1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 85-92% | 95-104% | 98-105% | 90-98% |
| EDTA plasma(n=5) | 87-103% | 78-90% | 78-91% | 91-98% |
| heparin plasma(n=5) | 88-97% | 79-98% | 91-98% | 97-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:PROM1) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| J Thorac Cardiovasc Surg | Clinical and biological significance of stem-like CD133+ CXCR4+ cells in esophageal squamous cell carcinoma PubMed: 26092504 |
| Journal of Histochemistry & Cytochemistry | Hyperglycemia Alters the Protein Levels of Prominin-1 and VEGFA in the Retina of Albino Rats pubmed:29076766 |
| Analyst | Matter, energy and information network of graphene-peptide-based fluorescent sensing system for molecular logic computing, detection and imaging of cancer stem?… Pubmed: 30785136 |
| Advanced Healthcare Materials | Impact of Hydrogel Elasticity and Adherence on Osteosarcoma Cells and Osteoblasts Pubmed: 30838809 |
| JOURNAL OF CANCER | Prognostic value of stem cell markers in esophageal and esophagogastric junction cancer: a meta-analysis Pubmed: 32368307 |
| Expression of CD44 and CD133 markers in regional metastases from breast cancer. | |
| Materials | Antibody CD133 Biofunctionalization of Ammonium Acryloyldimethyltaurate and Vinylpyrrolidone Co-Polymer-Based Coating of the Vascular Implants 33321837 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB516Hu01 | Recombinant Prominin 1 (PROM1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB516Hu01 | Polyclonal Antibody to Prominin 1 (PROM1) | WB; IHC; ICC; IP. |
| LAB516Hu71 | Biotin-Linked Polyclonal Antibody to Prominin 1 (PROM1) | WB; IHC; ICC. |
| LAB516Hu81 | FITC-Linked Polyclonal Antibody to Prominin 1 (PROM1) | WB; IHC; ICC; IF. |
| MAB516Hu22 | Monoclonal Antibody to Prominin 1 (PROM1) | WB; IHC; ICC; IP. |