Skip to product information
1 of 1

Cloud-clone

SKU:LMS085Mi

Magnetic Luminex Assay Kit for Angiotensin 1-7 (Ang1-7) ,etc.

Magnetic Luminex Assay Kit for Angiotensin 1-7 (Ang1-7) ,etc.

Regular price $932.00 USD
Regular price Sale price $932.00 USD
Sale Sold out
Shipping calculated at checkout.
Detection range
Size
Sensitivity

Product No.

LMS085Mi

Organism Species

Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

0.78-800pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.26 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity for detection of Angiotensin 1-7 (Ang1-7) ,etc..
100% cross-reactivity of Angiotensin 1-7 (Ang1-7) ,etc. was observed among Human, Mouse, Rat.

Recovery

Matrices listed below were spiked with certain level of recombinant Angiotensin 1-7 (Ang1-7) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin 1-7 (Ang1-7) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-101 96
EDTA plasma(n=5) 78-94 80
heparin plasma(n=5) 84-96 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin 1-7 (Ang1-7) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin 1-7 (Ang1-7) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin 1-7 (Ang1-7) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-99% 89-103% 88-105% 95-103%
EDTA plasma(n=5) 93-101% 90-104% 87-94% 87-97%
heparin plasma(n=5) 93-102% 80-101% 87-96% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:Ang1-7) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

     

    Magazine Citations
    J Stroke Cerebrovasc Dis Improvement of Plasma Biomarkers after Switching Stroke Patients from Other Angiotensin II Type I Receptor Blockers to Olmesartan PubMed: 25891757
    Cellular Physiology and Biochemistry Angiotensin-(1-7) in Paraventricular Nucleus Contributes to the Enhanced Cardiac Sympathetic Afferent Reflex and Sympathetic Activity in Chronic Heart Failure Rats pubmed:28848201
    Frontiers in Physiology Hydrogen Sulfide Attenuates Atherosclerosis in a Partially Ligated Carotid Artery Mouse model via Regulating Angiotensin Converting Enzyme 2 Expression pubmed:29066981
    Molecular Medicine Reports The ACE2-Ang (1-7)-Mas receptor axis attenuates cardiac remodeling and fibrosis in post-myocardial infarction. pubmed:28656296
    Journal of Clinical Pharmacy and Therapeutics Relationship between genetic variants of ACE2 gene and circulating levels of ACE2 and its metabolites. pubmed:28895159
    Molecular Medicine Reports Effects of IQP, VEP and Spirulina platensis hydrolysates on the local kidney renin angiotensin system in spontaneously hypertensive rats pubmed:28944898
    Open Journal of Endocrine and Metabolic Diseases Paper Submission A Study of the Correlation between Angiotensin (1-7) and the Histopathological Changes in the Penises of Experimentally Diabetic Rats 2-1980272_83198.htm
    Journal of the American Society of Hypertension Mesenchymal stem cell–derived microvesicles alleviate pulmonary arterial hypertension by regulating renin-angiotensin system Pubmed:29752040
    Innate Immunity  Lipoxin A attenuates LPS-induced acute lung injury via activation of the ACE2-Ang-(1-7)-Mas axis Pubmed:29969931
    Evidence-based Complementary and Alternative Medicine  Acute Biochemical, Cardiovascular, and Autonomic Response to Hyperbaric (4 atm) Exposure in Healthy Subjects Pubmed:29977313
    European Journal of Obstetrics & Gynecology and Reproductive Biology The impact of ovulation inducing drugs on carcinogenesis
    European Journal of Obstetrics & Gynecology and Reproductive Biology Changes of angiotensin II (1–8) and angiotensin (1–7) levels in early and late-onset preeclampsia
    Journals of Gerontology Series A-Biological Sciences and Medical Sciences Therapeutic Delivery of Ang (1-7) Via Genetically Modified Probiotic: A Dosing Study. Pubmed: 31586210
    journal of the european academy of dermatology and venereology Significance of the angiotensin I/angiotensin II/angiotensin‐(1‐7) axis in the pathogenesis of systemic sclerosis Pubmed: 31746507
    Medicine Alteration and association between serum ACE2/angiotensin (1-7)/Mas axis and oxidative stress in chronic kidney disease: A pilot study Pubmed: 32756181
    Dikkat Eksikliği Hiperaktivite Bozukluğu Tanısı Olan Anjiyotensin I, II, III, Alamandin peptid, Anjiyotensin Dönüştürücü Enzim (ACE), NADPH Oksidaz Enzim Serum …
    Amino Acids Angiotensin-(1¨C7) attenuates collagen-induced arthritis via inhibiting oxidative stress in rats 33398523
    Autoimmunity The prevalence and role of functional autoantibodies to angiotensin-converting-enzyme-2 in patients with systemic sclerosis 33910447
    researchsquare Ang-(1-7) Protects Skeletal Muscle Function in Aged Mice
    Peptides Angiotensin-(1-7) protects against sepsis-associated left ventricular dysfunction induced by lipopolysaccharide 34298021
    BMC Musculoskeletal Disorders Ang-(1–7) protects skeletal muscle function in aged mice 34548056
    J Cardiovasc Pharmacol Resveratrol Confers Protection Against Ischemia/Reperfusion Injury by Increase of Angiotensin (1-7) Expression in a Rat Model of Myocardial Hypertrophy 34232225
    Catalog No. Related products for research use of Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
    CPS085Mi21 OVA Conjugated Angiotensin 1-7 (Ang1-7) Immunogen; SDS-PAGE; WB.
    CPS085Mi11 BSA Conjugated Angiotensin 1-7 (Ang1-7) Immunogen; SDS-PAGE; WB.
    PAS085Mi08 Polyclonal Antibody to Angiotensin 1-7 (Ang1-7) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
    MAS085Mi22 Monoclonal Antibody to Angiotensin 1-7 (Ang1-7) WB; IHC; ICC; IP.
    MAS085Mi21 Monoclonal Antibody to Angiotensin 1-7 (Ang1-7) WB; IHC; ICC; IP.
    CES085Mi ELISA Kit for Angiotensin 1-7 (Ang1-7) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMS085Mi Magnetic Luminex Assay Kit for Angiotensin 1-7 (Ang1-7) ,etc. Magnetic Luminex Assay for Antigen Detection.
    View full details