Cloud-clone
SKU:LMB688Hu
Magnetic Luminex Assay Kit for Interleukin 21 (IL21) ,etc.
Magnetic Luminex Assay Kit for Interleukin 21 (IL21) ,etc.
Couldn't load pickup availability
Product No.
LMB688Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Interleukin 21 (IL21) ,etc..
No significant cross-reactivity or interference between Interleukin 21 (IL21) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Interleukin 21 (IL21) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 21 (IL21) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-98 | 85 |
| EDTA plasma(n=5) | 78-90 | 82 |
| heparin plasma(n=5) | 82-90 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 21 (IL21) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 21 (IL21) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 21 (IL21) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 78-102% | 88-95% | 98-105% | 87-102% |
| EDTA plasma(n=5) | 97-105% | 94-101% | 90-98% | 94-101% |
| heparin plasma(n=5) | 87-94% | 79-90% | 80-95% | 97-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:IL21) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Neurological Sciences | Serum IL-21 levels decrease with glucocorticoid treatment in myasthenia gravis Pubmed: 23708911 |
| Physiological Research Pre-Press Article | Decrease in serum interleukin 21 levels is associated with disease activity improvement in patients with recent-onset rheumatoid arthritis Biomed: Source |
| BioMed Research International | Indoleamine 2, 3-Dioxygenase (IDO) Regulates Th17/Treg Immunity in Experimental IgA Nephropathy |
| Am J Transplant | Circulatory follicular helper T lymphocytes associate with lower incidence of CMV infection in kidney transplant recipients 34153157 |
| J Periodontol | Cytokine profile in serum and gingival crevicular fluid of children with inflammatory bowel disease: A case‐control study 34730850 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| APB688Hu61 | Active Interleukin 21 (IL21) | Cell culture; Activity Assays. |
| APB688Hu01 | Active Interleukin 21 (IL21) | Cell culture; Activity Assays. |
| RPB688Hu01 | Recombinant Interleukin 21 (IL21) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPB688Hu02 | Recombinant Interleukin 21 (IL21) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB688Hu01 | Polyclonal Antibody to Interleukin 21 (IL21) | WB; IHC |
| PAB688Hu02 | Polyclonal Antibody to Interleukin 21 (IL21) | WB; IHC; ICC; IP. |
| LAB688Hu71 | Biotin-Linked Polyclonal Antibody to Interleukin 21 (IL21) | WB; IHC; ICC. |
| LAB688Hu81 | FITC-Linked Polyclonal Antibody to Interleukin 21 (IL21) | WB; IHC; ICC; IF. |
| RAB688Hu21 | Recombinant Antibody to Interleukin 21 (IL21) | WB; IF; ICC; IHC; IP; FCM. |
| MAB688Hu22 | Monoclonal Antibody to Interleukin 21 (IL21) | WB; IHC; ICC; IP. |
| MEB688Hu | Mini Samples ELISA Kit for Interleukin 21 (IL21) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SEB688Hu | ELISA Kit for Interleukin 21 (IL21) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCB688Hu | CLIA Kit for Interleukin 21 (IL21) | Chemiluminescent immunoassay for Antigen Detection. |
| LMB688Hu | Magnetic Luminex Assay Kit for Interleukin 21 (IL21) ,etc. | Magnetic Luminex Assay for Antigen Detection. |