Cloud-clone
SKU:LMC028Hu
Magnetic Luminex Assay Kit for Interleukin 28B (IL28B) ,etc.
Magnetic Luminex Assay Kit for Interleukin 28B (IL28B) ,etc.
Couldn't load pickup availability
Product No.
LMC028Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.49-500pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.163 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Interleukin 28B (IL28B) ,etc..
No significant cross-reactivity or interference between Interleukin 28B (IL28B) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Interleukin 28B (IL28B) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 28B (IL28B) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 94-103 | 99 |
| EDTA plasma(n=5) | 82-105 | 86 |
| heparin plasma(n=5) | 95-103 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 28B (IL28B) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 28B (IL28B) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 28B (IL28B) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 82-93% | 87-94% | 79-90% | 83-91% |
| EDTA plasma(n=5) | 86-101% | 81-89% | 78-103% | 92-99% |
| heparin plasma(n=5) | 78-89% | 96-103% | 83-97% | 82-93% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:IL28B) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Journal of Antimicrobial Chemotherapy | Impact of IL28B gene polymorphisms on interferon-λ3 plasma levels during pegylated interferon-α/ribavirin therapy for chronic hepatitis C in patients coinfected with HIV PubMed: 22294646 |
| Cytokine | Different effects of three interferons L on Toll-like receptor-related gene expression in HepG2 cells. Pubmed: 24041672 |
| Hepatology | Polymorphisms in melanoma differentiation‐associated gene 5 link protein function to clearance of hepatitis C virus Pubmed:25130193 |
| Cytokine. | Increased concentration of interferon lambda-3, interferon beta and interleukin-10 in the cerebrospinal fluid of patients with tick-borne encephalitis Pubmed:25461389 |
| J Biomed Res. | Impact of IL28B gene polymorphisms rs8099917 and rs12980275 on response to pegylated interferon-α/ribavirin therapy in chronic hepatitis C genotype 4 … pmc:PMC4726832 |
| Journal of Biomedical Research | Impact of IL28B gene polymorphisms rs8099917 and rs12980275 on response to pegylated interferon-α/ribavirin therapy in chronic hepatitis C genotype 4 patients PMC4726832 |
| LUPUS | Collagen triple helix repeat containing-1: a novel biomarker associated with disease activity in Systemic lupus erythematosus Pubmed: 30336754 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| APC028Hu01 | Active Interleukin 28B (IL28B) | Cell culture; Activity Assays. |
| RPC028Hu01 | Recombinant Interleukin 28B (IL28B) | Positive Control; Immunogen; SDS-PAGE; WB. |
| LAC028Hu81 | FITC-Linked Polyclonal Antibody to Interleukin 28B (IL28B) | WB; IHC; ICC; IF. |
| LAC028Hu71 | Biotin-Linked Polyclonal Antibody to Interleukin 28B (IL28B) | WB; IHC; ICC. |
| MAC028Hu22 | Monoclonal Antibody to Interleukin 28B (IL28B) | WB; IHC; ICC; IP. |
| HEC028Hu | High Sensitive ELISA Kit for Interleukin 28B (IL28B) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SEC028Hu | ELISA Kit for Interleukin 28B (IL28B) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCC028Hu | CLIA Kit for Interleukin 28B (IL28B) | Chemiluminescent immunoassay for Antigen Detection. |
| LMC028Hu | Magnetic Luminex Assay Kit for Interleukin 28B (IL28B) ,etc. | Magnetic Luminex Assay for Antigen Detection. |