Cloud-clone
SKU:LMA483Hu
Magnetic Luminex Assay Kit for Endothelin Converting Enzyme 1 (ECE1) ,etc.
Magnetic Luminex Assay Kit for Endothelin Converting Enzyme 1 (ECE1) ,etc.
Couldn't load pickup availability
Product No.
LMA483Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
1.95-2000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.65 pg/mL.
UOM
1Plex2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Endothelin Converting Enzyme 1 (ECE1) ,etc..
No significant cross-reactivity or interference between Endothelin Converting Enzyme 1 (ECE1) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Endothelin Converting Enzyme 1 (ECE1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Endothelin Converting Enzyme 1 (ECE1) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-89 | 85 |
| EDTA plasma(n=5) | 89-98 | 94 |
| heparin plasma(n=5) | 83-97 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Endothelin Converting Enzyme 1 (ECE1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Endothelin Converting Enzyme 1 (ECE1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Endothelin Converting Enzyme 1 (ECE1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 78-103% | 95-105% | 97-105% | 80-99% |
| EDTA plasma(n=5) | 87-101% | 81-98% | 84-97% | 78-105% |
| heparin plasma(n=5) | 87-103% | 98-105% | 95-105% | 95-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:ECE1) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Placenta | Carbon monoxide attenuates bacteria-induced Endothelin-1 expression in second trimester placental explants Pubmed: 24731730 |
| The Journal of Heart and Lung Transplantation | The Role of the Endothelin-1 Pathway as a Biomarker for Donor Lung Assessment in Clinical Ex Vivo Lung Perfusion Sciencedirect:S1053249815000054 |
| J Neurochem. | Endothelin-converting enzymes degrade α-synuclein and are reduced in dementia with Lewy bodies. pubmed:28171705 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPA483Hu01 | Recombinant Endothelin Converting Enzyme 1 (ECE1) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA483Hu01 | Polyclonal Antibody to Endothelin Converting Enzyme 1 (ECE1) | WB; IHC; ICC; IP. |
| MAA483Hu22 | Monoclonal Antibody to Endothelin Converting Enzyme 1 (ECE1) | WB; IHC; ICC; IP. |
| SEA483Hu | ELISA Kit for Endothelin Converting Enzyme 1 (ECE1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMA483Hu | Magnetic Luminex Assay Kit for Endothelin Converting Enzyme 1 (ECE1) ,etc. | Magnetic Luminex Assay for Antigen Detection. |