SKU:LMB064Hu
Magnetic Luminex Assay Kit for Apoptosis Inducing Factor (AIF) ,etc.
Magnetic Luminex Assay Kit for Apoptosis Inducing Factor (AIF) ,etc.
Couldn't load pickup availability
Product No.
LMB064Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Apoptosis Inducing Factor (AIF) ,etc..
No significant cross-reactivity or interference between Apoptosis Inducing Factor (AIF) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Apoptosis Inducing Factor (AIF) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Apoptosis Inducing Factor (AIF) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 82-102 | 91 |
| EDTA plasma(n=5) | 80-93 | 85 |
| heparin plasma(n=5) | 89-96 | 93 |
| sodium citrate plasma(n=5) | 93-104 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apoptosis Inducing Factor (AIF) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 84-98% | 95-105% | 95-103% | 91-101% |
| EDTA plasma(n=5) | 92-101% | 96-103% | 91-99% | 86-101% |
| heparin plasma(n=5) | 92-99% | 79-103% | 92-99% | 92-104% |
| sodium citrate plasma(n=5) | 84-101% | 79-95% | 83-90% | 90-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:AIF) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| РОЛЬ АПОПТОЗ ИНДУЦИРУЮЩЕГО ФАКТОРА И ОКИСЛИТЕЛЬНОГО СТРЕССА ПРИ ХРОНИЧЕСКОЙ СЕРДЕЧНОЙ НЕДОСТАТОЧНОСТИ 616-005.8 | |
| NEUROCHEMISTRY INTERNATIONAL | Redox-active DJ-1 sustains brainstem cardiovascular regulation via maintenance of mitochondrial function during mevinphos intoxication Pubmed: 32650030 |
| Iranian Journal of Basic Medical Sciences | Chromon-3-aldehyde derivatives restore mitochondrial function in rat cerebral ischemia Pubmed: 32963739 |
| Journal of?Pharmaceutical Sciences | Correction of mitochondrial dysfunction by 4-hydroxy-3, 5-ditretbutyl cinnamic acid in experimental Alzheimer's disease induced by A¦Â injection in rats. |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB064Hu01 | Recombinant Apoptosis Inducing Factor (AIF) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB064Hu01 | Polyclonal Antibody to Apoptosis Inducing Factor (AIF) | WB,IHC,ICC/IF |
| MAB064Hu22 | Monoclonal Antibody to Apoptosis Inducing Factor (AIF) | WB; IHC; ICC; IP. |
| SEB064Hu | ELISA Kit for Apoptosis Inducing Factor (AIF) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCB064Hu | CLIA Kit for Apoptosis Inducing Factor (AIF) | Chemiluminescent immunoassay for Antigen Detection. |
| LMB064Hu | Magnetic Luminex Assay Kit for Apoptosis Inducing Factor (AIF) ,etc. | Magnetic Luminex Assay for Antigen Detection. |