FineTest
SKU:EH3005
Human Ep-CAM/CD326(Epithelial Cell Adhesion Molecule) ELISA Kit
Human Ep-CAM/CD326(Epithelial Cell Adhesion Molecule) ELISA Kit
Couldn't load pickup availability
Product Name
Human Ep-CAM/CD326(Epithelial Cell Adhesion Molecule) ELISA Kit
Alias
Ep-CAM ELISA Kit, CD326 ELISA Kit, 17-1A ELISA Kit, GA733-2 ELISA Kit, gp40 ELISA Kit, KS1 ELISA Kit, 4 ELISA Kit, M4S1 ELISA Kit, TACSTD1 ELISA Kit, TROP1 ELISA Kit, 17-1A ELISA Kit, 323 ELISA Kit, A3 ELISA Kit, ACSTD1 ELISA Kit, antigen identified by monoclonal AUA1 ELISA Kit, CD326 antigen ELISA Kit, Cell surface glycoprotein Trop-1 ELISA Kit, chromosome 4 ELISA Kit, surface marker ELISA Kit, 35kD glycoprotein ELISA Kit, DIAR5 ELISA Kit, EGP ELISA Kit, EGP-2 ELISA Kit, EGP314 ELISA Kit, EGP40 ELISA Kit, EpCAM ELISA Kit, Epithelial cell surface antigen ELISA Kit, Epithelial glycoprotein ELISA Kit, Epithelial glycoprotein 314 ELISA Kit, ESA ELISA Kit, GA733-2EGP34 ELISA Kit, hEGP314 ELISA Kit, HNPCC8 ELISA Kit, KS 1 ELISA Kit, 4 antigen ELISA Kit, KS1 ELISA Kit, 4 ELISA Kit, KSAHEA125 ELISA Kit, M1S2 ELISA Kit, M4S1Ly74 ELISA Kit, Major gastrointestinal tumor-associated protein GA733-2 ELISA Kit, MIC18MH99 ELISA Kit, MOC31 ELISA Kit, TACST-1 ELISA Kit, TACSTD1 ELISA Kit, TROP1CD326 ELISA Kit, Tumor-associated calcium signal transducer 1CO-17A ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
Ep-CAM/CD326 ELISA Kit allows for the in vitro quantitative determination of Ep-CAM/CD326 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
1.563-100IU/ml
Sensitivity
< 0.938IU/ml
Species
Human
UniProt ID
Standard Curve

Storage
2-8 ℃ for 6 months
Recovery
Matrices listed below were spiked with certain level of Ep-CAM/CD326 and the recovery rates were calculated by comparing the measured value to the expected amount of Ep-CAM/CD326 in samples.
|
Matrix |
Recovery range(%) |
Average(%) |
|
serum(n=5) |
91-103 |
97 |
|
EDTA plasma(n=5) |
90-98 |
93 |
|
heparin plasma(n=5) |
89-98 |
94 |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ep-CAM/CD326 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
|
Sample |
1:2 |
1:4 |
1:8 |
|
serum(n=5) |
85-92% |
89-99% |
88-103% |
|
EDTA plasma(n=5) |
86-101% |
84-96% |
88-92% |
|
heparin plasma(n=5) |
82-100% |
92-99% |
80-97% |
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only
Share