FineTest
SKU:EH1769
Human DVL1(Segment polarity protein dishevelled homolog DVL-1) ELISA Kit
Human DVL1(Segment polarity protein dishevelled homolog DVL-1) ELISA Kit
Couldn't load pickup availability
In your quest to understand DVL1, the segment polarity protein disheveled homolog DVL-1, rely on our Human DVL1 ELISA Kit (EH1769). This meticulously designed kit is engineered to provide accurate and efficient quantification of DVL1 levels in human samples, reinforcing data accuracy and trustworthiness.
Uncompromising Precision: The EH1769 kit guarantees the highest level of precision and accuracy in quantifying DVL1, fortifying the reliability and integrity of your research data.
Wide Detection Range: It accommodates a broad range of sample concentrations, making it suitable for diverse research applications.
User-Friendly Interface: The kit simplifies laboratory procedures with clear and intuitive protocols, optimizing the research process and user experience.
Efficiency in Time Management: Engineered for efficiency, it minimizes laboratory work time, ensuring the rapid generation of research results and enhancing overall research productivity.
Product Name
Human DVL1(Segment polarity protein dishevelled homolog DVL-1) ELISA Kit
Alias
DVL1 ELISA Kit, Segment polarity protein dishevelled homolog DVL-1 ELISA Kit, Dishevelled-1 ELISA Kit, DSH homolog 1 ELISA Kit, DVL ELISA Kit, dishevelled ELISA Kit, dsh homolog 1 ELISA Kit, Drosophila ELISA Kit, dishevelled 1 ELISA Kit, homologous to Drosophila dsh ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
DVL1 ELISA Kit allows for the in vitro quantitative determination of DVL1 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
0.156-10ng/ml
Sensitivity
< 0.094ng/ml
Species
Human
UniProt ID
Standard Curve

Storage
2-8 ℃ for 6 months
Recovery
Matrices listed below were spiked with certain level of DVL1 and the recovery rates were calculated by comparing the measured value to the expected amount of DVL1 in samples.
|
Matrix |
Recovery range(%) |
Average(%) |
|
serum(n=5) |
91-104 |
100 |
|
EDTA plasma(n=5) |
87-101 |
94 |
|
heparin plasma(n=5) |
86-103 |
94 |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DVL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
|
Sample |
1:2 |
1:4 |
1:8 |
|
serum(n=5) |
97-105% |
88-104% |
91-98% |
|
EDTA plasma(n=5) |
84-98% |
86-100% |
87-101% |
|
heparin plasma(n=5) |
81-90% |
82-98% |
82-98% |
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note