Skip to product information
1 of 1

FineTest

SKU:EH0079

Human CD23(Receptor II for the Fc Region of Immunoglobulin E) ELISA Kit

Human CD23(Receptor II for the Fc Region of Immunoglobulin E) ELISA Kit

Regular price $450.00 USD
Regular price Sale price $450.00 USD
Sale Sold out
Shipping calculated at checkout.
size
Sensitivity
Range

FcεRII|CD23|CLEC4J|Fc epsilon RII|FCER2|Fcer2a|IGEBF|Ly-42|BLAST-2|CD23A|CD23CD23 antigen|CLEC4JC-type lectin domain family 4 member J|C-type lectin domain family 4|member J|Fc fragment of IgE|low affinity II|receptor for|CD23|FCE2Fc fragment of IgE|low affinity II|receptor for|CD23A|fc-epsilon-RII|Fc-epsilon-RII|IGEBF|Immunoglobulin E-binding factor|low affinity immunoglobulin epsilon Fc receptor|Lymphocyte IgE receptor

Product Name

Human CD23(Receptor II for the Fc Region of Immunoglobulin E) ELISA Kit

Alias

FcεRII ELISA Kit, CD23 ELISA Kit, CLEC4J ELISA Kit, Fc epsilon RII ELISA Kit, FCER2 ELISA Kit, Fcer2a ELISA Kit, IGEBF ELISA Kit, Ly-42 ELISA Kit, BLAST-2 ELISA Kit, CD23A ELISA Kit, CD23CD23 antigen ELISA Kit, CLEC4JC-type lectin domain family 4 member J ELISA Kit, C-type lectin domain family 4 ELISA Kit, member J ELISA Kit, Fc fragment of IgE ELISA Kit, low affinity II ELISA Kit, receptor for ELISA Kit, CD23 ELISA Kit, FCE2Fc fragment of IgE ELISA Kit, low affinity II ELISA Kit, receptor for ELISA Kit, CD23A ELISA Kit, fc-epsilon-RII ELISA Kit, Fc-epsilon-RII ELISA Kit, IGEBF ELISA Kit, Immunoglobulin E-binding factor ELISA Kit, low affinity immunoglobulin epsilon Fc receptor ELISA Kit, Lymphocyte IgE receptor ELISA Kit

Detection Method

Sandwich ELISA, Double Antibody

Application

CD23 ELISA Kit allows for the in vitro quantitative determination of CD23 concentrations in serum, plasma, tissue homogenates and other biological fluids.

Size

96T

Range

31.25-2000pg/ml

Sensitivity

< 18.75pg/ml

Species

Human

UniProt ID

P06734

Standard Curve

Storage

2-8 ℃ for 6 months

Recovery

Matrices listed below were spiked with certain level of CD23 and the recovery rates were calculated by comparing the measured value to the expected amount of CD23 in samples.

Matrix

Recovery range(%)

Average(%)

serum(n=5)

88-103

95

EDTA plasma(n=5)

86-105

98

heparin plasma(n=5)

88-105

96

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD23 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample

1:2

1:4

1:8

serum(n=5)

85-102%

90-104%

96-104%

EDTA plasma(n=5)

88-98%

82-88%

82-101%

heparin plasma(n=5)

82-100%

80-97%

82-99%

CV(%)

Intra-Assay: CV<8%

Inter-Assay: CV<10%

Note

For Research Use Only

 

View full details