FineTest
SKU:EH0079
Human CD23(Receptor II for the Fc Region of Immunoglobulin E) ELISA Kit
Human CD23(Receptor II for the Fc Region of Immunoglobulin E) ELISA Kit
Couldn't load pickup availability
FcεRII|CD23|CLEC4J|Fc epsilon RII|FCER2|Fcer2a|IGEBF|Ly-42|BLAST-2|CD23A|CD23CD23 antigen|CLEC4JC-type lectin domain family 4 member J|C-type lectin domain family 4|member J|Fc fragment of IgE|low affinity II|receptor for|CD23|FCE2Fc fragment of IgE|low affinity II|receptor for|CD23A|fc-epsilon-RII|Fc-epsilon-RII|IGEBF|Immunoglobulin E-binding factor|low affinity immunoglobulin epsilon Fc receptor|Lymphocyte IgE receptor
Product Name
Human CD23(Receptor II for the Fc Region of Immunoglobulin E) ELISA Kit
Alias
FcεRII ELISA Kit, CD23 ELISA Kit, CLEC4J ELISA Kit, Fc epsilon RII ELISA Kit, FCER2 ELISA Kit, Fcer2a ELISA Kit, IGEBF ELISA Kit, Ly-42 ELISA Kit, BLAST-2 ELISA Kit, CD23A ELISA Kit, CD23CD23 antigen ELISA Kit, CLEC4JC-type lectin domain family 4 member J ELISA Kit, C-type lectin domain family 4 ELISA Kit, member J ELISA Kit, Fc fragment of IgE ELISA Kit, low affinity II ELISA Kit, receptor for ELISA Kit, CD23 ELISA Kit, FCE2Fc fragment of IgE ELISA Kit, low affinity II ELISA Kit, receptor for ELISA Kit, CD23A ELISA Kit, fc-epsilon-RII ELISA Kit, Fc-epsilon-RII ELISA Kit, IGEBF ELISA Kit, Immunoglobulin E-binding factor ELISA Kit, low affinity immunoglobulin epsilon Fc receptor ELISA Kit, Lymphocyte IgE receptor ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
CD23 ELISA Kit allows for the in vitro quantitative determination of CD23 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
31.25-2000pg/ml
Sensitivity
< 18.75pg/ml
Species
Human
UniProt ID
Standard Curve
Storage
2-8 ℃ for 6 months
Recovery
Matrices listed below were spiked with certain level of CD23 and the recovery rates were calculated by comparing the measured value to the expected amount of CD23 in samples.
|
Matrix |
Recovery range(%) |
Average(%) |
|
serum(n=5) |
88-103 |
95 |
|
EDTA plasma(n=5) |
86-105 |
98 |
|
heparin plasma(n=5) |
88-105 |
96 |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD23 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
|
Sample |
1:2 |
1:4 |
1:8 |
|
serum(n=5) |
85-102% |
90-104% |
96-104% |
|
EDTA plasma(n=5) |
88-98% |
82-88% |
82-101% |
|
heparin plasma(n=5) |
82-100% |
80-97% |
82-99% |
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only