FineTest
SKU:ECH0065
Chicken TIMP-2(Tissue Inhibitors of Metalloproteinase 2) ELISA Kit
Chicken TIMP-2(Tissue Inhibitors of Metalloproteinase 2) ELISA Kit
Couldn't load pickup availability
The Chicken TIMP-2 (Tissue Inhibitors of Metalloproteinase 2) ELISA Kit is a valuable research-grade tool designed for the quantitative measurement of TIMP-2 levels in chicken samples. TIMP-2 is a critical protein that regulates the activity of metalloproteinases in chickens, playing a key role in tissue remodeling and repair. This kit allows researchers and clinicians to accurately assess TIMP-2 levels in chicken biological samples. Key Features: High Specificity: This kit is specifically designed to detect chicken TIMP-2, ensuring minimal cross-reactivity and accurate results. Quantitative Measurements: Provides precise quantitative data for comparisons and data analysis. Versatile Application: Suitable for use in various chicken sample types, accommodating a wide range of research and clinical applications. User-Friendly: The kit includes all necessary components and detailed instructions for straightforward and efficient experimentation. Reliability: Rigorous quality control processes and calibration standards ensure the reliability and consistency of results. Enhance your research in avian tissue remodeling, wound healing, and metalloproteinase regulation with the Chicken TIMP-2 (Tissue Inhibitors of Metalloproteinase 2) ELISA Kit.
Product Name
Chicken TIMP-2(Tissue Inhibitors of Metalloproteinase 2) ELISA Kit
Alias
TIMP-2 ELISA Kit, Metalloproteinase inhibitor 2 ELISA Kit, Tissue inhibitor of metalloproteinases 2 ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
TIMP-2 ELISA Kit allows for the in vitro quantitative determination of TIMP-2 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
0.156-10ng/ml
Sensitivity
< 0.094ng/ml
Species
Chicken
UniProt ID
Standard Curve

Storage
2-8 ℃ for 6 months
Recovery
Matrices listed below were spiked with certain level of TIMP-2 and the recovery rates were calculated by comparing the measured value to the expected amount of TIMP-2 in samples.
|
Matrix |
Recovery range(%) |
Average(%) |
|
serum(n=5) |
90-105 |
97 |
|
EDTA plasma(n=5) |
92-102 |
96 |
|
heparin plasma(n=5) |
89-105 |
97 |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TIMP-2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
|
Sample |
1:2 |
1:4 |
1:8 |
|
serum(n=5) |
85-96% |
86-97% |
85-97% |
|
EDTA plasma(n=5) |
83-101% |
83-99% |
84-95% |
|
heparin plasma(n=5) |
84-100% |
82-96% |
86-100% |
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only
Share