Human TPO-Ab(anti-Thyroid-Peroxidase antibody) ELISA Kit
Overview
| Product name: | Human TPO-Ab(anti-Thyroid-Peroxidase antibody) ELISA Kit |
| Reactivity: | Human |
| Alternative Names: | TPO Ab; TPO-Ab |
| Assay Type: | Sandwich |
| Sensitivity: | 1.19 ng/mL |
| Standard: | 200 ng/mL |
| Detection Range: | 3.13-200 ng/mL |
| Sample Type: | serum, plasma, cell lysates, cell culture supernates and other biological fluids |
| Assay Length: | 2h |
| Research Area: | Signal transduction;Metabolic pathway;Infection immunity;Hormone metabolism;Dermatology; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TPO-Ab. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TPO-Ab. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TPO-Ab, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TPO-Ab in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 200.00 | 2.013 | 1.932 |
| 100.00 | 1.700 | 1.619 |
| 50.00 | 1.240 | 1.159 |
| 25.00 | 0.796 | 0.715 |
| 12.50 | 0.517 | 0.436 |
| 6.25 | 0.321 | 0.240 |
| 3.13 | 0.175 | 0.094 |
| 0.00 | 0.081 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant TPO-Ab and the recovery rates were calculated by comparing the measured value to the expected amount of TPO-Ab in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 78-91% | 84% |
| EDTA plasma(n=5) | 80-96% | 88% |
| Heparin plasma(n=5) | 78-92% | 85% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TPO-Ab and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 87-96% | 82-95% | 92-105% | 78-102% |
| EDTA plasma(n=5) | 83-96% | 79-93% | 88-97% | 81-103% |
| Heparin plasma(n=5) | 89-101% | 81-98% | 93-102% | 78-92% |