1
/
of
1
ELK Biotechnology
SKU:ELK8839
Cattle EDN1(Endothelin 1) ELISA Kit
Cattle EDN1(Endothelin 1) ELISA Kit
Regular price
$588.00 USD
Regular price
Sale price
$588.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Cattle EDN1(Endothelin 1) ELISA Kit
Overview
| Product name: | Cattle EDN1(Endothelin 1) ELISA Kit |
| Reactivity: | Cattle |
| Alternative Names: | ET1; PPET1; Preproendothelin-1; Big endothelin-1; EDN1 |
| Assay Type: | Sandwich |
| Sensitivity: | 4.74 pg/mL |
| Standard: | 1000 pg/mL |
| Detection Range: | 15.63-1000 pg/mL |
| Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Endocrinology;Cardiovascular biology; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cattle ET-1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Cattle ET-1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cattle ET-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cattle ET-1 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 1000.00 | 2.126 | 2.038 |
| 500.00 | 1.665 | 1.577 |
| 250.00 | 1.106 | 1.018 |
| 125.00 | 0.852 | 0.764 |
| 62.50 | 0.593 | 0.505 |
| 31.25 | 0.336 | 0.248 |
| 15.63 | 0.234 | 0.146 |
| 0.00 | 0.088 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant ET-1 and the recovery rates were calculated by comparing the measured value to the expected amount of ET-1 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 87-95% | 91% |
| EDTA plasma(n=5) | 81-95% | 88% |
| Heparin plasma(n=5) | 83-97% | 90% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ET-1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 88-103% | 83-94% | 92-105% | 89-97% |
| EDTA plasma(n=5) | 85-92% | 83-101% | 87-98% | 79-92% |
| Heparin plasma(n=5) | 86-97% | 88-95% | 92-101% | 87-98% |
Share